OTARI FS-96 Operation Manual Download Page 4

Congratulations on your purchase of the Otari FS-96!

The Otari FS-96 is a device for converting signal formats and
sample rates of digital audio signals. A total of five professional
digital audio formats (ADAT, AES/EBU, SDIF-2, TDIF-1, OPTION)
are supported and 24 channels of digital audio signals can be
converted simultaneously to all of the signal formats available on
the FS-96, at the desired sample rate.

In addition to the format and sample rate conversion capabilities,
the FS-96 can be used as a digital signal router and the
connections between the input and output channels can be
changed internally without changing any physical connections.

SETUP

ROUTING

SRC

AES  

EBU

96kHz

48kHz

44.

1kHz

32kHz

INT

EXT

INPUT

ADAT

SDIF

-2

TDIF

-1

OPTION

PRESET

ENTER

CANCEL

1 :

1

1

2

3

4

POW

ER

FORMA

T & SAMPLE  RA

TE  CONVERTER

FS-

-96

Five Digital Audio Formats:

The FS-96 supports five digital

audio formats (ADAT, AES/EBU, SDIF-2, TDIF-1, OPTION). The
digital audio signals input in any of these formats can be output
in all of the formats available on the FS-96.

24-channel Capacity with Signal Routing Function:

The

FS-96 can handle 24 channels of audio inputs at the same time.
By using the signal routing function, the connections between
the input and output channels can be changed internally without
changing any physical connections.

96 kHz Sample Rate & 24-bit Quantization:

The FS-96

supports sample rates of 32 kHz to 96 kHz and bit resolution of
16 to 24 bit. By using the internal sample rate converters, the
sample rate and bit resolution of the input audio can be changed
as desired.

Same Format Sample Rate Conversion:

Whenever audio is

input in a given format, the output for that same format is also
available, and it can be sample rate converted to the same
output format if needed.

Accurate Clock Generation Circuit:

The FS-96 is equipped

with an accurate clock generation circuit for achieving signal
accuracy at professional level . Even unstable digital inputs can
be regenerated as accurate outputs.

Preset Memories for Operation and Routing Settings:

A maximum of 10 preset memories can be used for storing each
of operation and routing settings. Furthermore, combinations of
operation and routing memories can be stored into four PRESET
keys and they can be recalled by merely pressing a PRESET key.

Various Signal Synchronization:

The output audio can be

synchronized to any of three signals — FS-96’s internal clock
signal, external Word Clock signal, and the input audio signal.

Linking Multiple Units with Sample Accuracy:

Multiple FS-

96 units can be synchronized with phase-level sample accuracy
by linking the units using Word Clock signals.

Bi-directional Conversion with TDIF and AES/EBU:

Simultaneous bi-directional signal format conversions are
possible between the TDIF-1 and AES/EBU interfaces. This
mode is provided especially for digital recorders having the TDIF-
1 interfaces.

Status Data Editing Function:

It is possible to edit the

status data contained in each of the digital audio formats.

Expansion with Option Slots:

An option slot is provided on

the rear panel to accept a new digital audio format by inserting
an expansion module.

Comprehensive Operations with LCD:

All system

configurations are done in menu-driven screens via the LCD.

19" Standard Rack:

Each FS-96 includes a set of adapters

for installing into a standard 19-inch rack. The FS-96 occupies
only a 2U rack space.

Universal Power Supply Included:

The FS-96 is equipped

with a universal power supply circuit which supports AC voltages
and frequencies used all over the world. 

4

February 2001

Getting Started

Welcome to Otari FS-96

Main Features

Summary of Contents for FS-96

Page 1: ...t Signals 9 Connecting TDIF 1 Format Signals 9 Basic Operation Powering Up 10 Basic Setup Instructions 10 Operations with LCD 11 Modes of Operation 11 Resetting All Settings 12 Using Key Lock Function...

Page 2: ...is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the...

Page 3: ...to fit contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the polarized plug If this product is equipped with a three wire grounding type plug a plug having a...

Page 4: ...o available and it can be sample rate converted to the same output format if needed Accurate Clock Generation Circuit The FS 96 is equipped with an accurate clock generation circuit for achieving sign...

Page 5: ...s Alesis Lightpipe A dedicated optic fiber cable is used for connecting 8 channels of digital audio The FS 96 provides three systems of ADAT interfaces for handling a total of 24 channels SDIF Sony Di...

Page 6: ...channels are connected to the same output channels 10 Source indicators AES EBU ADAT SDIF 2 TDIF 1 OPTION Display the selection of the input format If no signal is present or synchronization to the i...

Page 7: ...requires a Word Clock signal for synchronization a SYNC connector BNC type is provided for each of input and output connector 22 WORD IN connector Used to connect an external Word Clock signal which i...

Page 8: ...frequencies 50 60 Hz used all over the world CAUTION To prevent damage to the FS 96 and the connected equipment do not connect or disconnect the cables while the machines are turned on Grounding The F...

Page 9: ...n connector input male output female for connecting a maximum of 24 channels of audio Note that the Word Clock signal needs to be connected via the BNC connector for synchronization Pin Assignment 1 3...

Page 10: ...N Channel Grouping All digital formats above are grouped in 8 channel groups except for SDIF 2 which is grouped in a single 24 channel group on a 50 pin connector Group A 1 8 Group B 9 16 Group C 17 2...

Page 11: ...24 channels of digital audio The input digital audio signals will be converted to all of the signal formats available on the FS 96 When the FS 96 is in Normal mode all advanced functions are availabl...

Page 12: ...all connectors are disconnected and then re connected the phase level synchronization of the input signals will be lost In this case the following screen appears on the LCD to alert the operator sinc...

Page 13: ...nfiguration modes will be stored into the preset memories which are currently used When changing the operation parameters confirm that the desired memory numbers are displayed on the initial screen Se...

Page 14: ...ING MEM 1 ROUTING MEM 0 ROUTING COPY 0 1 SETTING COPY 0 1 SETTING MEM 0 ROUTING MEM 0 ENTER SETTING MEM 0 ROUTING MEM 0 14 February 2001 Operating Memories Duplicating Preset Memories Clearing Preset...

Page 15: ...e preset memory is recalled Storing into a Preset To store the current combination of the setting and routing memories hold the desired PRESET key down and press the ENTER key When the memory combinat...

Page 16: ...tup mode and return to the initial screen Setup Mode Screens Setup mode consists of the following screens INPUT FORMAT screen p 17 used to select the input signal format This screen is also used when...

Page 17: ...s are available in the INPUT FORMAT screen AES selects the AES EBU AES3 format ADAT selects the ADAT optical format SDIF selects the SDIF 2 format TDIF selects the TDIF 1 format BDIR used to place the...

Page 18: ...sing YES After the desired option is selected press the ENTER key to change the status of the SRC USE TO SELECT YES NO 4 When INT is selected select a frequency of the signal and press the ENTER key W...

Page 19: ...the devices there are slight fluctuations or jitters in the sample rates of digital audio signals The FS 96 is equipped with an accurate clock generation circuit and the input audio signals can be con...

Page 20: ...ing Dither Function When the bit resolution is decreased the dither function can be activated for the audio data About Dither Function When the bit resolution is changed in a decreasing direction e g...

Page 21: ...initial screen List of Status Data The following status data can be edited on the FS 96 AES EBU EMPH emphasis indicates the emphasis status of the AES EBU signals The following options are available T...

Page 22: ...5 When the parameters are set to the desired values press the CANCEL key to return to the SYNC TIMING screen Or press the SETUP key to return to the initial screen Parameters in SYNC TIMING Screen Th...

Page 23: ...een by pressing the upper lower Arrow keys 2 Press the ENTER key to select the screen The current contrast setting is displayed as a graph 3 Adjust the screen contrast with the right left Arrow keys a...

Page 24: ...uration of the signal routing is made by assigning the input channels to the output channels When configuring the signal routing follow the instructions below 1 Select the desired routing memory numbe...

Page 25: ...rters cannot be changed Even if the sample rate converter is activated it will be turned off automatically by entering into Bi Direction mode If the sample rate converter is turned on the following sc...

Page 26: ...nce 75 both input output Connector BNC type x 2 input x 1 output x 1 Digital Audio Format ADAT AES EBU SDIF 2 TDIF 1 An option slot for the expansion module is provided on the rear panel Number of Cha...

Page 27: ......

Page 28: ...noga Park California 91304 U S A Phone 1 818 598 1200 Fax 1 818 594 7208 Otari Europe GmbH Rudolf Diesel Strasse 12 D 40670 Meerbusch Germany Phone 49 2159 50861 Fax 49 2159 1778 Otari Singapore Pte L...

Reviews: