The status data are contained in each of the digital audio formats
to indicate the status of the audio signals. The FS-96 can edit
the status data for each format.
NOTE:
The settings of the status data editing screens are
normally set to “THRU”. The status data of the input signals are
not changed and are output to the external devices as they are.
The status data should be set properly
according to the actual signal status. If the
status data do not match the actual signal
status, the signal may not be reproduced
properly on the destination devices.
1.
Press the
SETUP
key to place the FS-96 in Setup mode
and select the
OUTPUT STATUS
screen by pressing the
upper & lower Arrow keys.
The status data setting screen is displayed on the LCD.
2.
Select the desired item with the upper & lower Arrow
keys and press the
ENTER
key to activate the
parameter.
The current selection is displayed with parentheses and the
other choices are displayed on the screen.
(USE
TO SELECT ITEM)
3.
Select the desired value with the right & left Arrow keys
and press the
ENTER
key to store the selection.
The selection is stored into the current setting memory and
is reflected onto the actual setting.
(USE
TO CHANGE PARAMETER)
4.
Repeat the steps 2 and 3, until all of the desired
parameters are set.
5.
After all settings are finished, press the
CANCEL
key to
return to the
OUTPUT STATUS
screen. Or, press the
SETUP
key to return to the initial screen.
■
List of Status Data:
The following status data can be edited
on the FS-96.
■
■
AES/EBU EMPH. (emphasis):
indicates the emphasis status
of the AES/EBU signals. The following options are available:
THRU (same as input), 50/15 (50/15 µs), CCITT, OFF, NO
INDICATE (no indication).
■
■
AES/EBU FREQ. (frequency):
indicates the sample rate of
the AES/EBU signals. The following options are available:
THRU (same as input), 32k, 44k, 48k, 88k, 96k, NO INDICATE
(no indication), AUTO (interlocked to reference clock).
■
■
SDIF EMPH. (emphasis):
indicates the emphasis status of
the SDIF-2 signals. The following options are available: THRU
(same as input), ON, OFF.
■
■
TDIF EMPH. (emphasis):
indicates the emphasis status of
the TDIF-1 signals. The following options are available: THRU
(same as input), ON, OFF.
■
■
TDIF BIT RES. (bit resolution):
indicates the bit resolution of
the TDIF-1 signals. The following options are available: THRU
(same as input), 24BITS, 20BITS, 16BITS, AUTO (interlocked
to output bit resolution).
■
■
TDIF FREQ. (frequency):
indicates the sample rate of the
TDIF-1 signals. The following options are available: THRU
(same as input), 32k, 44k, 48k, OTHER, AUTO (interlocked to
reference clock).
NOTE:
The FS-96 cannot edit any status data which are not
mentioned above. Such status data will not be changed from
those of input signals.
The status data are used only to indicate the
signal status. Note that the actual signal will
not be changed by editing the status data.
AES/EBU EMPH.: 0
CCITT
ENTER
AES/EBU EMPH.: 0
015 <CCITT> OFF
AES/EBU EMPH.: 0
NID <THRU > 5015
ENTER
AES/EBU EMPH.: 0
THRU
AES/EBU EMPH.: 0
THRU
ENTER
OUTPUT STATUS: 0
February 2001
21
Setup Mode
Editing Status Data
Summary of Contents for FS-96