A S S E M B L Y   I N S T R U C T I O N

If there is not enough knowledge always turn to a pro-
fessional when mounting.  
•  The fan should be mounted according to this assem-
 bly 

instruction.

•  The fan must be mounted to roof curb (TFU, see 
  sep. assembly instruction Art.no 1270370). 
•   The fan should be installed in a safe way and make 
  sure that no foreign objects are left behind.
•   The fan should be installed in a way that makes ser-
  vice and maintenance easy. 
•   The fan should be installed in a way that vibrations 
  not can be transferred to duct or building. To provi-
  de this, use for example a flange.
•  Consider the weight of the fan. 
•  TKV/TKH (except TKV/TKH 560 A1)  is provided 
  with handles on each side.

•  Make sure that the access cable is not damage when 
  mounting and installation.
•  NB! Do not start the fan before mounted.
•  Before starting the fan the installation must be in-
 spected.
•  Consider the placement, so there is enough space 
  when open the fan for cleaning and maintenance.
•  Pay attention to the placement of the connection 
  cable, to prevent damage when maintaining the fan.

E N G L I S H

The junction box has a mounting plate 
which is mounted with screws in pre-
punched holes on the fan or on the roof curb. 
There are also holes on the mounting plate for Östberg 
Safety switch E 31 663 10 (Art.no 4020174).

Mounting holes for M8 screws for 
mounting on to Östberg TFU. 
These are plugged so an alternatively 
mounting may be used.

Lock the fan 
to the inlet with 
4x M8 screws.

12 pcs alternative 
mounting holes 
around inlet frame
(Ø 6 mm).

1270366_utg5_TKV_TKH_SV_EN.indd   11

2020-01-07   11:06:15

1270366_utg5_TKV_TKH_SV_EN.pdf   11

1270366_utg5_TKV_TKH_SV_EN.pdf   11

2020-01-07   11:11:04

2020-01-07   11:11:04

Summary of Contents for TKH 560

Page 1: ...or use Takfl ktar TKV TKH Roof fans TKV TKH SVENSK ENGLISH VERSION 1270366_utg5_TKV_TKH_SV_EN indd 1 2020 01 07 11 05 17 1270366_utg5_TKV_TKH_SV_EN pdf 1 1270366_utg5_TKV_TKH_SV_EN pdf 1 2020 01 07 11...

Page 2: ...r transport av brand och explo sionsfarliga mnen slipdamm sot o dyl F r maximal livsl ngd vid installation i fuktig eller kall milj b r TKV TKH vara i kontinuerlig drift Fl kten f r ej vara i drift i...

Page 3: ...an utf ras Fl kten ska monteras s att ev vibrationer ej kan verf ras till kanalsystem och byggnadsstomme Anv nd t ex dukstos f r detta Beakta fl ktarnas vikt vid montering TKV TKH utom TKV TKH 560 A1...

Page 4: ...ddsjord h ll sladden kort och med s lite induktans som m jligt Se till att det r till r ckligt avst nd mellan elledningar och motorns styrkablar f r att undvika st rningar OBS S kerst ll r tt polarite...

Page 5: ...g erfordras vid reng ring Fl ktens lager r underh llsfria och ska endast bytas vid behov Vidreng ring av fl kten f r h gtryckstv tt eller starka l sningsmedel ej anv ndas Reng ring m ste ske p ett s d...

Page 6: ...fr n skador stiger moduleringen propor kylning av sluten orsakade av alltf r h ga inre tempera tionellt igen regulatorn turer Vid en temperatur kning ver gr nsv rdet reduceras kontrollniv n proportion...

Page 7: ...men 6 x Rel ej draget IGBT Fel EC enheten st ngs av anslutning Kortslutning mot jord eller kortslut nya f rs k till omstart efter 11 14 ning i motorlindning ca 60 sek Kod 9 bruten Slutgiltig avst ngni...

Page 8: ...er x EN 61000 6 1 2007 Elektromagnetisk kompatibilitet EMC Generella fordringar Immunitet hos utrustning i bost der kontor butiker och liknande milj er x EN 61000 6 2 2005 Elektromagnetisk kompatibili...

Page 9: ...andards x EN 61000 6 1 2007 Electromagnetic compatibility EMC Generic standards Immunity for residential commercial and light industrial environments x EN 61000 6 2 2005 Electromagnetic compatibility...

Page 10: ...by per sons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given super vision or instruction concerning use of the a...

Page 11: ...n mounting and installation NB Do not start the fan before mounted Before starting the fan the installation must be in spected Consider the placement so there is enough space when open the fan for cle...

Page 12: ...ro tective ground keep cable short and with as little inductance as possible Pay attention to sufficient distance from power lines and motor wires to pre vent interferences Attention Ensure correct po...

Page 13: ...is closed and locked before starting Make sure that there is no noise from the fan F A U L T D E T E C T I O N 13 E N G L I S H M A I N T E N A N C E Attention look out for sharp edges and corners Lo...

Page 14: ...bridged 2 x Energized Active temperature monitoring terminals The device has an active temperature At sinking temperature the Check cooling 11 14 monitoring to protect it from damage modulation rises...

Page 15: ...ower supply 6 x De energized IGBT Fault EC Controller switches off renewed terminals Shortcut earth or shortcut of motor attempt to start after about 60 sec 11 14 winding Code 9 Final shutoff if inter...

Page 16: ...dustrigatan 2 Avesta Tel 46 226 860 00 Fax 46 226 860 05 E mail info ostberg com www ostberg com 1270366_utg5_TKV_TKH_SV_EN indd 16 2020 01 07 11 06 17 1270366_utg5_TKV_TKH_SV_EN pdf 16 1270366_utg5_T...

Reviews: