POWER KNEE is suitable for use in any environment except where spillage or immersion in water or any other fluid 
is possible, or where exposure to highly electrical and/or magnetic fields can occur (e.g., electrical transformers, 
high-power radio/TV transmitters, RF surgical equipment, CT and MRI scanners). The battery charger and power 
supply are for indoor use only.

Make sure that no component of the prosthesis or accessories has been altered or tampered with.

Keep fingers away from the back side of the prosthesis joint to prevent the risk of pinching in the event of flexion. 
Keep fingers away from the front side bumpers to prevent the risk of pinching during extension. 

(Figure2)

Visually inspect the prosthesis before each use.

If you experience any problems with a component of the prosthesis or accessories that are not documented in this 
manual, contact your Össur representative. Never attempt to make any technical repairs yourself.

Caution: 

Avoid exposure to rain, snow, ice, or salt. Maintain and store in a clean and dry condition.

Caution: 

Avoid exposure to intense dust or smoke or to excessive mechanical shocks or vibrations. Avoid impact to 

the battery.

Caution: 

Use the prosthesis at temperatures between –10°C and +40°C.

Caution: 

Power on the prosthesis only when you are wearing it.

Caution: 

Follow recommended maintenance intervals.

INDICATIONS FOR USE

The POWER KNEE is designed for patients with transfemoral and knee disarticulation amputation. The healthcare 
practitioner must provide each patient with training for appropriate use and proper application of the system. 
Limited to community and workplace ambulators with the ability or potential to traverse through most 
environmental barriers such as curbs, stairs or uneven surfaces. Low to moderate impact only.

CONTRAINDICATIONS FOR USE

N/A.

SYSTEM OVERVIEW

PROSTHESIS & BATTERY (Figure 3)

BATTERY CHARGER & POWER SUPPLY (Figure 4)

PREPARATION FOR USE

CHECKING THE BATTERY STATUS (Figure 5)

Check the battery status on the battery at the front of the prosthesis. To check the battery status, press the battery 
status button:

1. If five LEDs go on, the battery is fully charged. 

2. If only the bottom LED goes on, the battery is nearly depleted and needs to be charged.
3. If no LED goes on, the battery is totally depleted and needs to be charged.

4. If five LEDs flash, the battery needs to undergo a 

“self-maintenance”

 process and needs to be charged.

5. If five LEDs go on in a wave-like pattern this indicates that self maintenance process will take place the next 

time the battery is inserted into the charger. The LEDs will then indicate the battery status.

Summary of Contents for Power Knee

Page 1: ...POWER KNEE Instruction for Use...

Page 2: ...USE 7 OPERATION 9 TECHNICAL DATA 12 MAINTENANCE 13 STORAGE TRANSPORT CONDITIONS 13 PARTS ORDERING 13 WARRANTY 13 DISPOSAL OF EQUIPMENT 13 PRODUCT CERTIFICATION INFORMATION 13 BLUETOOTH MODULES REGULAT...

Page 3: ...EDs C B A Rear of prosthesis On Off switch Prosthesis status LED Front of prosthesis Battery Lock tab 1 2 Front Back Battery status button On Off switch Prosthesis status LED Battery status LEDs 4 5 6...

Page 4: ...Front Battery Fan Status LED Battery charger Battery charger Power inlet Power supply Wall outlet Charging Flashes Charge completed Steady Problem Battery charger status LED OK Prosthesis Status LED P...

Page 5: ...action INTENDED USE POWER KNEE is designed for transfemoral and knee disarticulation amputees with moderate to high activity level In addition POWER KNEE can be used for an extended user population na...

Page 6: ...nd manner To protect natural resources and to promote material reuse please separate batteries and electronic components from other types of waste and recycle them through your local free electronic p...

Page 7: ...ures between 10 C and 40 C Caution Power on the prosthesis only when you are wearing it Caution Follow recommended maintenance intervals INDICATIONS FOR USE The POWER KNEE is designed for patients wit...

Page 8: ...escending beep is heard and the prosthesis status LED goes off A Caution Never remove the battery if the prosthesis is not powered off as data could be lost 3 Push down the lock tab as shown in B belo...

Page 9: ...adjusts its behavior to activities like walking ascending or descending stairs ramps etc When none of these activities are detected it operates in standing state allowing you to move effortless in con...

Page 10: ...descending ramps and stairs KNEELING 1 Allow the prosthetic knee to reach the standing state 2 Place and maintain load onto the prosthesis 3 Put your sound leg in front of the prosthesis 4 Force the p...

Page 11: ...tivity feel the prosthesis temperature with your hand to confirm if this is the cause of the problem and let the prosthesis cool before resuming your current activity The risk of an overheat warning m...

Page 12: ...3 15 16 x 3 15 16 Weight 2 7 kg 6 lb w o battery Rating 50 4 VDC 25 A max Angle of knee flexion Max 120 Expected lifetime 5 years Foot Module Variflex LP Variflex Talux Variflex XC Re flex ShockTM Re...

Page 13: ...ANTY For warranty information see the POWER KNEE Warranty Card DISPOSAL OF EQUIPMENT Dispose of the POWER KNEE accessories in an environmentally responsible manner Never incinerate a battery as it may...

Page 14: ...rticular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tuning the equipment off and on the user is encouraged to try and co...

Page 15: ...d result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation Portable RF communications equipment including peripherals such...

Page 16: ...s 2 kV line s to earth Voltage Dips IEC61000 4 11 0 UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 0 UT 1 cycle and 70 UT 25 30 cycles Single phase at 0 Voltage Interruptions IEC61000 4 11 0 UT 250 3...

Page 17: ...8 710 704 787 LTE Band 13 17 Pulse modulation 217 Hz 9 745 780 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation 18 Hz 28 870 930 1720 1700 1990 GSM 1800 CDMA 1900 GSM 19...

Page 18: ...with other recommended ssur components If un usual movement or product wear is detected in a structural part of a device at any time the patient should be instructed to immediately discontinue use of...

Page 19: ...1 8152 Alcobendas Fax 86 21 6127 1799 Fax 1 866 441 3880 Madrid Espa a asia ossur com Tel 00 800 3539 3668 ssur Europe BV Fax 00 800 3539 3299 ssur Australia De Schakel 70 orders spain ossur com 26 Ro...

Reviews: