Ossila Slot-Die Coater
User Manual
Ossila.com
37
Ossila Limited © 2019
11.
Slot-Die Coater Troubleshooting
Problem
Possible cause
Action
No power /
display
The power switch on the unit is in the
OFF position
Check the connection and ensure the
power is turned ON
The power supply may not be
connected properly
Ensure the unit is firmly plugged in to the
power supply and the plug is firmly
connected to both the adapter and the
working power socket
The fuse on the rear panel has blown
Ensure the unit is unplugged. Check the
fuse on the rear panel. If it has blown,
replace with a suitably rated 5A slow
blow fuse
The power supply adapter has a fault
Contact Ossila for a replacement power
supply adapter
No obvious cause
If all the above causes have been
considered, there may be a fault on the
control board. Please contact Ossila for
information
Motor Stalled
(Syringe Pump)
Syringe has hit first safety switch
There is not enough solution in the
syringe and the moving part of the pump
has hit the safety switch. Load more
solution into the syringe so the plunger is
further back and try again
Crash Warning
The secondary safety switch has
accidentally been triggered
Switch the unit off and on again
The plunger pusher is triggering the
secondary safety switch
Rotate the lead screw by hand to move
the plunger pusher closer to the centre of
travel
Internal fault in the secondary safety
switch
If all the above has been considered
there may be a fault with the secondary
safety switch; contact Ossila for more
information