OSS OSS-CPCIe3-3U-10GbE-x4-QUAD Installation Manual Download Page 15

One Stop Systems 

 
 

OSS-CPCIe3-3U-10GbE-x4-QUAD                                                                                                                                                                                                   15 

 

 
 

10  Contacting Technical Support 

Our support department can be by phone at  

1 (760) 745-9883

. Support is available Monday through Friday, 8:00 AM to 5:00 PM PT. When 

contacting One Stop Systems Technical Support, please be sure to include the following information: 

1) Name 
2) Company Name 
3) Phone Number 
4) Fax Number 
5) Email Address 
6) Model Number 

7) Serial Number 
8) Computer Make 
9) Computer Model 
10) Operating System and Version 
11) Make/Model of accessories attached to the tablet 
12) Detailed description of the problem 

 

 

 

You can also visit our web site at:  

HT

www.onestopsystems/support/

T

 

 

OSS Sales Contact

[email protected]

 

 

OSS Support Contact

[email protected]

 

 

For a quick response, use the Technical Support and RMA Request Form available in the Support Section of the website. Simply complete the 
form with all required information. Please make sure that your problem description is sufficiently detailed to help us understand your problem.  

For example: Don’t say “Won’t boot up.” Do say “Tried all the steps in the Troubleshooting Section and it still won’t boot up.” 

For faster diagnosis of your problem, please run the two utility programs described in the following sections and include the diagnostic files 
they generate with your email. 

 

10.1  Returning Merchandise to One Stop Systems 

If factory service is required,  you must contact OSS Service Representative to obtain a Return Merchandise Authorization (RMA) number. Put 
this number and your return address on the shipping label when you return the item(s) for service. 

One Stop Systems  will return any product

 

that is not accompanied by an RMA number

.  Please note that One Stop Systems WILL NOT accept COD packages, so be sure to return the 

product freight and duties-paid.  

Ship the well-packaged product to the address below: 

RMA # ________ 

One Stop Systems 

2235 Enterprise Street, Suite#110 92029 

USA 

It is not required, though highly recommended, that you keep the packaging from the original shipment of your One Stop Systems product.  
However, if you return a product to One Stop Systems for warranty repair/ replacement or take advantage of the 30-day money back 
guarantee, you will need to package the product in a manner similar to the manner in which it was received from our plant.  One Stop Systems 
cannot be responsible for any physical damage to the product or component pieces of the product (such as the host or expansion interfaces for 
the PCIe expansion chassis) that are damaged due to inadequate packing.  Physical damage sustained in such a situation will be repaired at the 
owner’s expense in accordance with Out of Warranty Procedures.  Please, protect your investment, a bit more padding in a good box will go a 
long way to insuring the device is returned to use in the same condition you shipped it in. Please call for an RMA number first. 

Summary of Contents for OSS-CPCIe3-3U-10GbE-x4-QUAD

Page 1: ...INSTALLATION GUIDE OSS CPCIe3 3U 10GbE x4 QUAD OSS CPCIe3 3U 10GbE x4 QUAD www onestopsystems com ...

Page 2: ...rning ON the Device 8 7 LED Panel Indicator 8 8 Verify Device Installation 9 8 1 Linux 9 8 1 Windows 11 9 Troubleshooting 14 9 1 Device is not detected or recognized 14 9 2 Device is recognized but the front LED indicator is not coming ON 14 9 3 Intel82599 devices are showing UP with a Yellow Exclamation mark 14 9 4 Broken OSS 529 board 14 10 Contacting Technical Support 15 10 1 Returning Merchand...

Page 3: ...ctions for the following procedures Unpacking Description of Parts Module Installation SFP module and Cable Installation Turning ON the Device SFP module and Cable Installation LED Panel Indicator Verify Device Installation 2 Unpacking Check and identify the standard supplied item Inspect the card module to make sure it is free from physical defects damages ...

Page 4: ...One Stop Systems OSS CPCIe3 3U 10GbE x4 QUAD 4 3 Description of Parts Side Front ...

Page 5: ...uch exposed board end connectors or components on the printed circuit board when installing the module 4 Slowly insert the module in the chassis slot by placing the module card edges into the top and bottom card guides With the injector ejector handle in the down position carefully slide the module to the rear of the chassis Caution Ensure that the module is aligned perpendicularly to the chassis ...

Page 6: ...sh up on the injector ejector handle to complete insertion of the module and latch it into place 6 Secure the module front panel to the chassis using the captive front panel mounting screws The module has two captive mounting screws a 1st mounting screw on top b 2nd mounting screw bottom beneath the injector ejector ...

Page 7: ...port on the module 5 1 Supported SFP and SFP module What are the SFP and SFP module requirements for the Intel Ethernet Converged Network Adapter X520 Series Check Intel website for further information on the supported SFP and SFP modules https www intel com content www us en support articles 000005528 network and i o ethernet products html ...

Page 8: ...he SFP modules are inserted correctly you can turn ON the expansion unit After the expansion unit is powered UP the LED located on the front module will illuminate depending on the link connection either 1G or 10G 7 LED Panel Indicator 10g Indicates 10G link 1g Indicates 1G link ...

Page 9: ...elow on the terminal window lspci tv grep 82599 See output below four Intel 82599ES are detected lspci D grep Network Ethernet See output below four Intel 82399ES are detected To find out the device assigned name type the command below on the terminal window lspci c network businfo See output below four 82599ES are detected and each has their corresponding device name i e enp9s0f0 ...

Page 10: ...epresent the device slot address B D F Bus Device Function and its corresponding physical SFP port on the card The OSS PXIE 10GBe QUAD uses a PLX PEX 8732 You can check or query the PEX 8732 by using the command below on the terminal window lspci v grep I PEX 8732 See output below ...

Page 11: ...agement window Finally click on the View Menu and select View Devices by Connection Open ACPI BIOS Open PCI Bus Click the or sign several times until you reach a PCI Express Root Port Complex Then click or collapse all the or until you see multiple subsets of PCI standard PCI to PCI bridge See screenshot below Right click the PCI standard PCI to PCI bridge with your mouse then select properties Se...

Page 12: ...ign next to PCI standard PCI to PCI bridge and you will find four instances of Intel 82599 10 Gigabit Dual Port Network Connection devices see screenshot below The following four screenshots represent the Bus Device Function and its corresponding physical SFP port on the card ...

Page 13: ...One Stop Systems OSS CPCIe3 3U 10GbE x4 QUAD 13 ...

Page 14: ...ap the SFP module and cables 4 Re install the driver for the Intel82599 5 Replace the OSS 520 card with a known good card 9 3 Intel82599 devices are showing UP with a Yellow Exclamation mark 1 Install or re install the Intel82599 driver 2 Reboot the system after installing the driver 3 Re install OS 4 Install Operating System updates 9 4 Broken OSS 529 board 1 If you received a brand new DOA Dead ...

Page 15: ...One Stop Systems If factory service is required you must contact OSS Service Representative to obtain a Return Merchandise Authorization RMA number Put this number and your return address on the shipping label when you return the item s for service One Stop Systems will return any product that is not accompanied by an RMA number Please note that One Stop Systems WILL NOT accept COD packages so be ...

Page 16: ...One Stop Systems OSS CPCIe3 3U 10GbE x4 QUAD 16 ...

Reviews: