FIG.11: System Diagram-Snake Model (Direct View)
Signal
DC48V+
DC48V
–
DMX+
DMX
–
Address
Wire Size
1.0mm
²
1.0mm
²
0.3mm
²
0.3mm
²
0.3mm
²
Color
Red
Black
Green
Blue
Yellow
Connection
DC24V+
DC24V
– and GND
DMX+
DMX
–
Do not connect
Pin#
5
4
1
3
2
The Address wire only need to be connected during address configuration, it is not needed during operation.
This wiring diagram shows only typical connections. Actual wiring depends on LED Tube configuration and installation. Actual no.
vary according to cable
lengths and signal source. Please consult your local Traxon office for aid.
DMX In
300mm
LED Engine 24V
AC 220-240V In
Starter Cable
Installation engineer should use appropriate plugs for
outdoor connection.
End Cap
Tubes are daisy chained
Interconnection cable (optional)
Interconnection cable (mandatory)
C
o
lo
r
T
yp
e
M
ax
. S
ig
na
l D
ai
sy
C
ha
in
M
ax
. P
o
w
er
D
ai
sy
C
ha
in
P
S
U
P
o
w
er
R
G
B
W
12
m
8m
15
0W
R
G
B
17
m
8m
15
0W
D
W
25
m
8m
15
0W