These operating instructions are intended for operating personnel. 
1.  Please  make  yourself  familiar  with  the  notes  and  recommendations  of  these  operating 

instructions before assembly, starting and maintenance of the machine.  

2.  By  doing  so,  you  will  control  the  machine  in  a  safe  manner  and  enhance  its  performance. 

Servicing  and  maintenance  as  per  these  operating  instructions  improve  your  safety  and 
maintain the machine’s value. 

3.  The  manufacturer  accepts  no  liability  for  personal  injury  and  damage  to  property 

arising from improper use of the machine!

 

 
 

1. Safety regulations 

 
For your safety 
Before  starting  the  floor  cleaning  machine,  it  is  imperative  to  read  these  operating  instructions 
and always keep them ready at hand. 
The floor cleaning machine must not be used by persons which are not instructed in its use and 
expressly charged with its operation. 
 
Attention!    The  FloorXcenter  is  not  suited  for  the  treatment  of  surfaces  from  which  dusts  and 
liquids hazardous to health are being detached. Do not cross steps! 
 
Caution!  
Never cross over the electric cable with the machine. Danger of electric shock! 
 
General 
The operation of the FloorXcenter is subject to the current national regulations. 
Besides  the  operating  instructions  and  the  current  and  binding  regulations  concerning  accident 
prevention in the country of use, the approved technical rules for safe and professional working  
have to be adhered to also. Any operation method which can be deemed as critical or dangerous,  
in terms of safety must be refrained from. The use of the appliance on public ways and streets is 
not allowed. 
 
Use of the machine in accordance with regulations 

• 

The FloorXcenter is exclusively intended for internal use in buildings.  

• 

Any further use is not deemed to be in accordance with the regulations. The manufacturer will 
not  be  liable  for  any  damage  arising  from  such  use;  such  risks  and  the  results  thereof  are 
solely the liability of the user. 

• 

To use the machine in accordance with the regulations also means to observe the provisions 
concerning operation, maintenance and servicing specified by the manufacturer.  

• 

The  pertinent  rules  and  regulations  concerning  accident  prevention  as  well  as  all  other 
generally approved safety and working regulations have to be adhered to. 

• 

Unauthorized  modifications  of  the  machine  will  void  all  guarantees  and  the  liability  of  the 
manufacturer for any resulting damage. 

• 

Before using the machine, floor coverings have to be tested for their suitability for this cleaning 
method!  

• 

Mind  the  surface  pressure  with  point-elastic  floors,  e.g.  in  gyms,  use  with  caution  and  test 
appropriately before use!  

• 

The manufacturer is not liable for any damage caused to surfaces upon incorrect use of the 
machine or its accessories. 

 
 

Summary of Contents for FloorXcenter

Page 1: ... x White Pad 1 x Micro fibre Pad Read these instructions imperatively before operating the machine Operation Instructions Content 1 Safety regulation 2 Equipment configuration 3 Accessories 4 Basic cleaning extreme dirt 5 Refreshing of oiled surfaces with Osmo Liquid Wax Cleaner 6 Maintenance and re oiling of surfaces 7 Staining with Wood Wax Finishes and Polyx Professional Color Oil 8 Service 9 M...

Page 2: ... operating instructions and the current and binding regulations concerning accident prevention in the country of use the approved technical rules for safe and professional working have to be adhered to also Any operation method which can be deemed as critical or dangerous in terms of safety must be refrained from The use of the appliance on public ways and streets is not allowed Use of the machine...

Page 3: ...osition The operating position is behind the machine Admitted maintenance personnel The floor cleaning machine must not be maintained or serviced by persons which are not qualified to do so Cleaning agents For the use of cleaning agents and care products it is required to observe the hazard indications of the manufacturer wear safety goggles and protective clothing if appropriate Use only low foam...

Page 4: ...ries Following accessories are available Micro fibre pad Ø 33 cm Cleaning Pad white Ø 33 cm Brushing ring Cleaning Pad red Ø 33 cm Advice Never leave the FloorXcenter standing on a Cleaning Pad Micro fibre Pad or Brushing ring after use The weight of the machine will squeeze out any remaining fluid smooth and even application working can no longer be achieved If this occurs the pad brushing ring h...

Page 5: ...come onto the floor Advice push control device only for a short time Too much liquid may penetrate into the wood and lead to irreparable damages Move the FloorXcenter onto the dirty surface and begin work Advice work on approx 10 m Otherwise loosened dirt can dry again If FloorXcenter is laid on the floor close the lid in order to avoid the liquid to leak When lifting the machine the driving disc ...

Page 6: ... much material on the surface when you can see driving rings on the surface Turn the pad around or dry the pad on an untreated surface In order to get a shiny result polish up the surface after drying ca 30 minutes with a new white pad 6 Maintenance and re oiling of surfaces At first clean the surface see point 4 With stubborn dirt use a red pad if necessary Re oil extremely worn out surfaces with...

Page 7: ...ing please contact your specialized wholesale dealer or one of the service stations Attention This machine is only intended for use on surfaces with a maximal gradient of 2 Attention The use of this machine on public ways and streets is not allowed 9 Maintenance it is imperative to observe the following notes For cleaning and maintenance of the machine the replacement of parts or switching to anot...

Page 8: ...e toxic hazardous to health caustic or irritating Corrective maintenance inclusive of the integration of spray leads and hoses may only be carried out by approved after sales service points or competent qualified personnel being familiar with all relevant safety regulations 10 Technical Data A C motor 230 V 50 Hz Rated power 290 W 1 9 A Oscillation speed 1 450 1 min Brush 330 mm Working height 250...