SKYPOWER
™
The SkyPower
™
system supplies AC power to the platform
through an AC receptacle to run tools, lights, cutting, and weld
-
ing equipment.
All power regulation components are located in a watertight box
connected by cable to the generator. The generator supplies
power when running at the specified speed with the power
switch on (switch is located on platform). A three-pole, 30 Amp
circuit breaker protects the generator from overload.
Generator Output
ANSI Specifications:
• 3-phase: 240 V, 60 Hz, 7.5 kW
• 1-phase: 240 V/120 V, 60 Hz, 6 kW
CE Specifications:
• 3-phase: 240 V, 7.5 kW, 18.3 A, 1.0-pf
• 1-phase: 240 V, 6.0 kW, 26 A, 1.0-pf
• 1-phase: 120 V, 6.0 kW, 50 A, 1.0-pf
Peak:
• 3-phase: 8.5 kW
• 1-phase: 6.0 kW