SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
3121132
– JLG Lift –
6-15
6.4 OPERATOR MAINTENANCE
TO AVOID PERSONAL INJURY, USE SAFETY PROP FOR ALL MAINTE-
NANCE REQUIRING PLATFORM TO BE ELEVATED.
NOTE:
Be sure to lubricate like items on each side.
NOTE:
Recommended lubricating intervals are based on
machine operations under normal conditions. For
machines used in multi-shift operations and/or exposed to
hostile environments or conditions, lubrication frequen-
cies must be increased accordingly.
Operate hydraulic functions through one complete cycle
before checking hydraulic oil level in tank. Oil should be
visible in ADD sight window on hydraulic tank. If oil is not
visible, add oil until oil is visible in both ADD and FULL
sight windows on tank. Do not overfill tank.
Any time the pump coupling is removed, coat splines of
coupling with Texaco Code 1912 grease prior to assem-
bly.
1.
Fuel Tank
Fuel - Diesel or Gasoline
Capacity - 31.5 gal (119 l)