SECTION 3 - GENERAL ELECTRICAL INFORMATION & SCHEMATICS
3-8
– JLG Lift –
3121801
Disassembly
5. Insert a 4.8 mm (3/16”) wide screwdriver blade between the mating seal and one of the red wedge lock tabs.
6. Pry open the wedge lock to the open position.
7. While rotating the wire back and forth over a half turn (1/4 turn in each direction), gently pull the wire until the contact is
removed.
Figure 3-10. Connector Disassembly
NOTE:
The wedge lock should never be removed from the housing for insertion or removal of the contacts.
Wedge Lock
The wedge lock has slotted openings in the forward, or mating end. These slots accommodate circuit testing in the field, by
using a flat probe such as a pocket knife. DO NOT use a sharp point such as an ice pick.