SECTION 2 - PROCEDURES
2-10
– JLG Lift –
3121801
1. A special tool is used to install a new rod seal into
the applicable cylinder head gland groove.
WHEN INSTALLING "POLY-PAK" PISTON SEALS, ENSURE SEALS
ARE INSTALLED PROPERLY. REFER TO WIPER SEAL INSTALLA-
TION FOR CORRECT SEAL ORIENTATION. IMPROPER SEAL
INSTALLATION COULD RESULT IN CYLINDER LEAKAGE AND
IMPROPER CYLINDER OPERATION.
2. Use a soft mallet to tap a new wiper seal into the
applicable cylinder head gland groove. Install a new
wear ring into the applicable cylinder head gland
groove.
3. Place a new o-ring and back-up seal in the applica-
ble outside diameter groove of the cylinder head.
4. Install washer ring onto rod, carefully install the head
gland on the rod, ensuring that the wiper and rod
seals are not damaged or dislodged. Push the head
along the rod to the rod end, as applicable.
5. Carefully slide the piston spacer on the rod.
6. If applicable, correctly place new o-ring in the inner
piston diameter groove. (The backup ring side fac-
ing the O-ring is grooved.)
Figure 2-7. Rod Seal Installation
Figure 2-8. Wiper Seal Installation
Figure 2-9. Installation of Head Seal Kit
Summary of Contents for JLG 260MRT
Page 1: ...Service Maintenance Manual Model 260MRT 3121801 April 19 2013...
Page 2: ......
Page 8: ...iv JLG Lift 3121801 TABLE OF CONTENTS This page left blank intentionally...
Page 22: ...SECTION 1 SPECIFICATIONS 1 14 JLG Lift 3121801 NOTES...
Page 66: ...SECTION 2 PROCEDURES 2 44 JLG Lift 3121801 NOTES...
Page 91: ...SECTION 3 GENERAL ELECTRICAL INFORMATION SCHEMATICS 3121801 JLG Lift 3 25 NOTES...
Page 95: ...SECTION 3 GENERAL ELECTRICAL INFORMATION SCHEMATICS 3121801 JLG Lift 3 29 NOTES...
Page 104: ...SECTION 3 GENERAL ELECTRICAL INFORMATION SCHEMATICS 3 38 JLG Lift 3121801 NOTES...
Page 105: ......