background image

Combination of PC-250 with NR-12-TRS-2 and Eurotronik-10 

Netz 230V

1/N/PE 

11

12

13

14

4

7

6

5

8

U1

N

N

L1

Magnetventil 230V

Elektroden

3/N/PE

Wicklungsschutz

Filterpumpe

Temperaturfühler

Heizungspumpe

W

Netz 400V

Dosiertechnik

Dosier-
pumpe

N

Netz 230V

1/N/PE 

Ausgang

Pumpe

Druckschalter

Netz 230V

1/N/PE 

Stellantrieb

Geöffnet bei "Rückspülen und "Klarspülen",

geschlossen bei "Filtern"

Auffangbehälter

11 12 13 14 U1 V1 1 N

SKSK

W W

L1 L2 L3 N

22

L1

U2 N 20 2130 31 2 3 4

5

5

4

3

2

L1 N

N

U2 U3

10 11

 

 
 

Summary of Contents for POOL-Control-250

Page 1: ...pecifications Dimensions 220mm x 220mm x 100mm Operational voltage 400V 50Hz Control system power consumption ca 10VA Switching capacity Pump max 3 0 kW AC3 Heater max 2A Dosing system max 8A Protecti...

Page 2: ...ng switching times 8 Start backflushing process manually 8 Info key 8 Installation 9 Electrical power supply 9 Mains connection when using 400V 3 phase pump 10 Mains connection when using 230 V AC pum...

Page 3: ...n on time 17 Heater priority circuit 18 Solar heater priority circuit 18 Frost protection 19 Pump time 19 heater time 19 Solar time 19 Motor defect 19 Phase fields 19 Int backflushing intern 19 Ext Ba...

Page 4: ...y This controller is not usable for other types of solar collector Terminals for electronic level regulation NR 12 TRS 2 Art No 3030075020 enable convenient automatic regulation of the swimming pool w...

Page 5: ...R ck sp len The filter pump is switched on because backflushing is taking place using the bar valve connected Klar sp len The filter pump is switched on because rinsing is taking place using the bar v...

Page 6: ...he control system this indicator lamp is used to show the current operating status of the solar heater Backflushing process indicator lamp This indicator lamp always illuminates if backflushing or rin...

Page 7: ...y shows 0 00 0 00 1 the minute display of the top time switch on time blinks Note if you press the key the current time will be taken over 3 You can now use the and keys to set the required switch on...

Page 8: ...et the minutes If you press the key the current time is taken over 4 Press the key again the hours in the switch on time blink You can now use the and keys to set the hours 5 Press the key again the s...

Page 9: ...display automatically Installation The controller must be protected against moisture in accordance with its protection class and the fixed to a plain fireproof support with suitable loading capacity...

Page 10: ...L1 N WSK schutz 230V max 8A Filterpumpe max B16A Vorsicherung FI Schalter Netz 1 N 230V 50Hz 25A 0 03A N kontakt The bridge fitted in the works between the terminals labelled WSK must be removed if a...

Page 11: ...N A 230 V bar valve for rinsing can be connected to terminals U4 and N Both valves will be controlled by the internal backflushing controller Heater and dosing systems are blocked during the backflus...

Page 12: ...h good heat transfer between temperature sensor and swimming pool water an immersed sleeve R Art No 3200200003 should be built into the piping system The sensor polarity is as required A solar tempera...

Page 13: ...e right Fuses The electronic control system is protected by a 0 25A fine wire fuse on the PCB in the inside of the device The short circuit protection for the filter pump must be provided by a backup...

Page 14: ...tched off temporarily by the EUROTRONIK 10 or the NR 12 TRS 2 level regulation system Backflushing The filter pump is switched on because backflushing is taking place using the bar valve Rinsing The f...

Page 15: ...defective Caution If both temperature sensors are at the same temperature the solar sensor must never display a higher value than the water temperature sensor otherwise the solar heater will not swit...

Page 16: ...e value is 0 the largest 15 3 If you press the key again the normal diagnosis display appears and the filter unit continues to operate The adjusted value will be saved automatically A temperature diff...

Page 17: ...d the filter unit is switched off and the display shows the following Min Solar s Minimale Einschaltzeit der Solarheizung 120 2 Use the and keys to change the minimum time in stages of 10s The smalles...

Page 18: ...3 If you press the key again the normal diagnosis display appears and the filter unit continues to operate The additional heater priority is switched off at the works Solar heater priority circuit Thi...

Page 19: ...ump time This line displays the total operating hours for the filter pump heater time This line displays the total operating hours for the additional heater Solar time This line displays the total ope...

Page 20: ...he filter pump operating status is displayed in the top line of the service terminal the pump can be switched on or off manually 1 Once the key has been pressed the filter unit is switched off and the...

Page 21: ...tinues to operate Dosing unit When the dosing unit operating status is displayed in the top line of the service terminal it can be switched on or off manually 1 Once the key has been pressed the filte...

Page 22: ...ormal diagnosis display appears and the filter unit continues to operate Diagnosis This menu is only accessible for trained osf service technicians Language When the language is shown in the top line...

Page 23: ...ungsschutz Filterpumpe Temperaturf hler Heizungspumpe W Netz 400V Dosiertechnik Dosier pumpe N Netz 230V 1 N PE Ausgang Pumpe Druckschalter Netz 230V 1 N PE Stellantrieb Ge ffnet bei R cksp len und Kl...

Page 24: ...PC 250 Filter control unit operating manual Page 24 24...

Reviews: