3.3.1 Minimum Clearances
Minimum Clearances to Combustibles are:
A. Alcove width:
54-1/2“(1384mm) D. Side panel to Sidewall: 13-1/2“ (343mm)
B. Ceiling Height:
50“(1270 mm)
E. Alcove Depth:
26“ (660mm)
C. Top of unit to ceiling:
20-1/2“ (521mm) F: Back of unit to back wall: 4“ (102mm)
Floor:
0” (0mm) – Note: Check local codes for floor requirements.
Corner:
4”
(102mm)
A
B
C
D
D
C
B
E
F
Figure 4
CAUTION:
Due to high temperatures, the appliance should be located out of traffic and away from
furniture and draperies. Provide a minimum 48" (1219 mm) front clearance to the unit.
Note:
The appliance may be installed directly on combustible flooring providing the unit
stability is maintained. Although the back wall and corner clearance is 4” (102mm), we
recommend 6" (150mm) for fan installation and removal.