Everest Fireplace Installation and Operation Manual
50 ______________________________________________________________________________
12.
For installations where more than one chimney is located in the same non-chase or within the
same area, we suggest that their terminations be separated by at least 16" (410 mm)
horizontally, and 18" (460 mm) vertically. This separation is to prevent smoke migrating from
one chimney to another.
7.6
CHIMNEY INSTALLATION INSTRUCTIONS
Always refer to the chimney manufacturer’s Ins
tallation manual to ensure a safe installation. Some
non-illustrated parts may be required.
7.6.1
RECOMMENDED MEASUREMENTS
A
To insure a good draft, it is
recommended to have a length of 18
inches from the
top of the unit
to the
first offset. However, starting using a
30° or 45° elbow is also approved.
B
Mandatory measure of 15 ft. from the
bottom of the fireplace to the top of
the outside chimney.