Everest Fireplace Installation and Operation Manual
78 ______________________________________________________________________________
3.
Secure the ducting (A)
to the 90° elbows (E)
with
self-tapping
screws (3 per elbow).
Insert the frames (F) in
the elbow (E). Set hot
air
outlet
frames
behind
the
non-
combustible
materiel
and secure to the wall
with screws. Secure the
frames (F) to the
elbows (E) with 3 self-
tapping screws each.
Secure the hot air
outlet grilles (G) to the
frames with screws.
4.
Maintain at least a 2" (50 mm) clearance between the ducts and the firestop; the required hole
size for the hot air grilles (outlet) is 8¼" × 8¼" (210 mm × 210 mm).
5.
Only one elbow by duct is allowed.
6.
Maintain at least 12" (254 mm) clearance from the outlets grilles framing to a combustible
ceiling, side wall or mantel.