Instruction Manual
1-888-543-6473
1-888-541-6474
13376 Comber Way
Surrey BC V3W 5V9
[email protected]
www.ortechindustries.com
375 Admiral Blvd
Missis
s
auga
,
ON L5T 2N1
LED Security Light
Sensors
MODEL
OL-
S
CAUTION
INSTALLATION GUIDE
1. Turn OFF all power by removing fuse or flipping circuit breaker to OFF position
2. Screw motion sensor arm into the desired hole on junction box's cover plate.
Ensure that the sensor is positioned as shown with the LEDs on top.
3. Connect wires. Connect WHITE wires together using wire nuts provided. Connect BLACK
house wire to BLACK wire from sensor. Connect the RED wire from the sensor to the
BLACK wire(s) from the light fixture(s) using the wire nut provided. Tighten securely.
Carefully push all of the wires into the junction box. (See the diagram on the left)
NEUTRAL = White LIVE = Black RED = Load
DO NOT MOUNT ON THE GROUND. Recommended installation height is 6-1/2ft to 10ft/
This product is intended for use with enclosed gasket and with a junction box marked for
use in wet locations. Before you begin, make sure that your power is turned OFF at your
circuit breaker box. DO NOT rely on the switch power being turned OFF.
1. Install the cross bar to the junction box and secure with the (2) mounting screws. If installing to a wall or building, pre-drill holes and use
appropriate plugs / anchors. Once your holes are drilled, you can install the cross bar to the surface using the two mounting screws
2. On the cross bar locate GND, attach the ground wire with the grounding screw to the cross bar
3. Use a wire nut to connect the ground wire to the house ground wire (typically copper).
For proper connection, place wire nut over wires and twist clockwise until tight
4. Connect supply wires with wire nuts. BLACK supply wire connects to the BLACK power supply wire (Live).
WHITE product wire connects to the WHITE supply wire (Neutral)
5. You may use the optional gasket at this time round
6. Install the light fixture to the cross bar. Use silicon sealant (not included) around the perimeter of the light to seal for moisture
7. Screw in the stainless steel screw to hold fixture in place. Insert plastic screw cover into screw hole
8. Turn ON your electricity after the installation has been completed
9. Turn ON power switch. (if power is NOT ON, the light will NOT cycle ON or OFF)
Adjusting Your Motion Sensor
Your sensor head can be adjusted by turning the individual
light head to detection area.
You can also adjust your sensor head up and down to your detection distance.
REMINDER: If fixture is mounted higher
than
8
ft (2.4m),
aiming the sensor
down will reduce coverage distance.
The detector is less sensitive to motion
directly towards it.
Rotate joint for
left and right
directions (180°)
Rotate joint for
left and right
direction (180°)
Installation
For easy installation, select tan existing light operated by a wall switch for replacement.
For best performance, mount the fixture about 8 ft (2.4m) above the ground.
If fixture is mounted higher than 8 ft (2.4m), aiming the sensor down will reduce coverage distance.
Setting the Motion Sensor
•
Detection Range: 70 ft
•
Detection Angle: 240°
CAUTION
KEEP THE SENSOR AT LEAST
2" (51 mm) AWAY FROM
THE LAMPS.