1.
Reboot the WRZ device.
2.
Press the reset button 2.1 Front panel0) around 5s while the device is booting and
release the button when the status led is blinking.
3.
The status LED should light red (See
).
4.
Wait until the recovery image is loaded from QSPI dataflash (This can take more
than 1 minute).
8.3.1.2
From Serial UART
The recovery mode can also be started from Uboot console (Connected to the serial
RJ45-UART) when it is not possible to access the reset button:
1.
Press any key when seeing:
Loading wr7shw preboot...
U-Boot 201X.xx-wr7s-vX.X (Jun 25 2018 - 16:07:12) ZENv3
WR_ZEN-vx.x-Sxx_xxx
Hit any key to stop autoboot: 0
2.
Execute:
wr7s-uboot> env run recoveryboot
3.
Wait until the recovery image is loaded from QSPI dataflash (This can take more
than 1 minute).
8.4
Factory Config Mode
In case a miss configuration of the device invalids its correct login, one can manually reset
the configuration to default factory value by following the steps below:
1.
Reboot the WRZ device.
2.
Press the CTRL/Info button more than 15s while Uboot is loading.
3.
Hold until reset factory message appears on LCD status LED light in yellow (See
).
4.
Wait until the device reboot with default factory parameters.
132
CHAPTER
8
•
WR-Z16 User Manual Rev. v3.4
8.4 Factory Config Mode
Summary of Contents for Seven Solutions WR-ZEN Series
Page 1: ...WR Z16 MODEL User Manual Revision v3 4 Date 14 October 2022 ...
Page 2: ......
Page 4: ...Blank page II WR Z16 User Manual ...
Page 38: ...BLANK PAGE 3 2 Connecting to the Device 28 CHAPTER 3 WR Z16 User Manual Rev v3 4 ...
Page 104: ...BLANK PAGE 6 5 Firewall 94 CHAPTER 6 WR Z16 User Manual Rev v3 4 ...
Page 144: ...BLANK PAGE 8 5 Failsafe Mode 134 CHAPTER 8 WR Z16 User Manual Rev v3 4 ...
Page 167: ...V Virtual Clock 47 W Web GUI 32 White Rabbit 2 58 WR 2 WRZ OS 3 WR Z16 User Manual iii INDEX ...