TROUBLESHOOTING
1. General
Procedure for fault isolation on board uses the visual indicator of the ELT’s front
panel. This visual indicator is activated by a self-test capability within the ELT.
2. Faults on Self-test
A. Visual indicator
When the self-test is carried out, the number of flashes gives an indication of
the faulty parameter detected during the self-test.
(1)3+1 flashes
- Low battery voltage:
Check battery, refer to relevant CMM for tests and repair.
(2) 3+2 flashes
- Low RF power:
Check 406 MHz power, refer to relevant CMM for tests and repair.
(3) 3+3 flashes
- Faulty VCO locking (faulty frequency):
Check 406 MHz frequency, refer to relevant CMM for tests and repair.
(4) 3+4 flashes
- No identification programmed;
- Check if the dongle (if applicable) or the ELT is properly programmed.
NOTE: For servicing instructions, refer to Service Letter SL S18XX50X-25-02
Maintenance Policy for KANNAD ELTs found on the Support section of Orolia
Website:
Repair and battery replacement can only be carried out
by PART 145 / FAR 145 avionics workshops
(or equivalent agreement according to local regulations).
Additional approval from Orolia is required. Refer to Service Letter SL
S18XX50X-25-02 Maintenance Policy for KANNAD ELTs.