TECHNICAL DATA
Type:
GSM controller
Receiver supply voltage:
12VDC
Max. load:
2300W
Color:
White
Ingress protection:
IP20
Receiver dimensions:
76 x140x27mm
Other features:
Programming via PC
QUICK START GUIDE
The first step is to add an Administrator number:
-
Connect the power supply, press and hold the RESET button for approx. 3 sec,
-
when the GSM diode blinks call the Sim card number in the controller from the Admin phone.
Function
SMS command
Feedback
Change password from 1234 to 1212.
1234CP1212
CP:1212
Manual addition of number 111222333.
1212AD111222333#
SET OK.
Manual deletion of number 111222333.
1212DD111222333#
DELETED.
Enable adding numbers by voice call.
1212ADD ON
ALLOW TO ADD USER NUMER
Disable adding numbers by voice call.
1212ADD OFF
DISABLE ADDING USER NUMER
Delete all numbers.
1212FD
FD OK
Addition of 222333444 with a limit of 12.
1212LIMIT222333444*012#
SET OK.
Enable feedback to the Administrator.
1212SMS1#
SET OK.
Disable feedback to the Administrator.
1212SMS0#
SET OK.
Access for all numbers.
1212ATH0#
ANY CALLER ID
Access for a restricted number list.
1212ATH1#
AUTHORIZATION MODE OK or SET MODE OK
Controller status monitoring.
CHK
RELAY1:OFF
RELAY2:OFF
MODE:A
PASSWORD:1212
FREE MEMORY:1022
AUTHORIZATION
CALLER ID
SIGNAL STRENGTH:21V
Output activation (can also be called).
ON1
(OUT1 ON)
Activation of A-mode - setting an opening time of 5 sec.
1212MA5#0
SET OK.
Output activation (can also be called).
ON1
(OUT1 ON)
Activation of B-mode with feedback.
1212MB1#
SET MODE OK.
Activation of B-mode without feedback.
1212MB0#
SET MODE OK.
Output setting.
ON1
(OUT1 ON)
Output setting.
OFF1
(OUT1 OFF)
Activation of E-mode (Bistable mode)
1212ME0#1
SET OK.
COMPLETE USER MANUAL
1. Setting the administrator number
Function
SMS command
Feedback
1.1 Setting the administrator number
by voice call
-
connect the power supply, press and hold the RESET button for approx. 3 sec,
-
when the blue (GSM) LED starts blinking call the Sim card number in the controller from the
Admin phone,
- you will receive a reply back, which means that you have set up your Administrator number
correctly
- to change the Administrator number again follow the above instructions.
- SAVE ADMIN OK
1.2 Setting the administrator number
by SMS
Assuming that the Administrator's number is 666 555 444
- send a text message:
1234ADMIN666555444#
- you will receive a reply back,
- to change the Administrator number again follow the above instructions.
- SAVE ADMIN OK
1.3 Password change
(factory default password: 1234)
- to change the factory-set password, send an SMS to the Sim card number in the controller:
1234CP1212 (new password: 1212)
- you will receive a reply back, which means that you have correctly changed your password to
1212