MMI8000 Series

MMI8056, MMI8070, MMI8080, MMI8100, MMI8104, MMI8121

Installation Instructions

1.0 Installation and Startup Guide

Install Environment
Where Used

The MMI8000 Series is designed for industrial environments. The operating temperature range is 32 to 113 °F (0
to 45 °C). It may not be suitable for using in certain outdoor applications. Please consult the factory for advised
usage in outdoor applications.

NEMA Rating

The MMI8000 Series front bezel is NEMA 4 rated. When installed properly in a NEMA 4 panel, the NEMA 4 rating
of the panel is not compromised. This means that fluids do not enter the panel during wash downs.

Electrical Environment

The MMI8000 Series has been tested to conform to European CE requirements. This means that the circuitry is
designed to resist the effects of electrical noise. This does not guarantee noise immunity in severe cases. Proper
wire routing and grounding insures proper operation.

Mechanical Environment

Avoid installing units in environments where severe mechanical vibration or shocks are present.

2.0 Installation Instructions

2.1 Mounting Instructions

2.1.1 Location Considerations

Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC output
modules, contactors, starters and relays, and any other source of electrical interference are located away from the
back of the unit.

Take particular note as to the position of variable speed drives and switching power supplies. Their input and load
cables should be screened to a central star earth point.

Summary of Contents for MMI8056

Page 1: ...s has been tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Prop...

Page 2: ...humidity are present This causes condensation of water in the device Do not install these terminals in environments where inflammable gases are present 2 2 Power Connections Make sure that all local...

Page 3: ...from any other branch 2 2 3 CE Requirements To make an MMI8000 comply with EMC directives and to reduce susceptibility to electrical interference a separate 14 AWG ground wire should be taken to the...

Page 4: ...permission of the National Electrical Manufacturers Association from NEMA ICS 3 304 2 3 Communications Connections The ports as you look at the back of the case are the ports for connecting to a PLC o...

Page 5: ...a Rx 3 Tx Tx 4 Tx Tx 5 GND Signal Ground Signal Ground Signal Ground Signal Ground 6 Data Data 7 TxD Transmit 8 RxD Receive 9 Data Data 2 3 3 USB Host port Supports various devices with USB interface...

Page 6: ...ctManager or EasyBuilder8000 to change modes ON OFF OFF OFF Force to Touch Adjust mode Used for touchscreen calibration Reset project memory and settings to default OFF OFF ON OFF Force to Boot ROM Lo...

Page 7: ...e reset again by inputting YES Click OK The default password 111111 is restored However other passwords including download and upload password must be reset Note When the reset action is taken saved p...

Page 8: ...re IP65 front panel O ring seal Operating Temperature 0 45 C Operation humidity 10 90 RH non condensing Enclosure Plastic Dimensions WxHxD 323 x 243 x 51mm 286x212x50mm 240x179x50mm 204x150x48mm Panel...

Page 9: ...9 Dimensions Drawings are not to scale and are for visual purposes only MMI8121 MMI8100 8104 MMI8080...