8
Heater turn-on temperature
This parameter sets the temperature above which the heater turns on and starts operating. The
heater will turn off when the temperature falls down by 10 °C below the temperature set on the
sensor. Temperature change range: 40 °C to 120 °C.
extinguish time control
This parameter allows for setting the fan operation (extinguish) when the temperature on the
sensor falls down to 30 °C . Setting range: 0 - 45 minutes.
Blow through - operation time
This parameter sets the fan time operations when the BLOW THROUGH function is on. Time range:
0 to 90 seconds.
Blow through - pause time
This parameter sets the pause time for fan operation (in minutes) between blowthroughs. Time
range: 1 - 60 minutes.