Temperature range
- 58 °C to + 390 °C
Boiler temperature settings
+ 50 °C to + 120 °C
Heater temperature settings
+ 40 °C to + 120 °C
Smooth blow-through control
yes
Controllable min. fan power
30 - 70 %
Controllable max. fan power
30 - 100 %
Fan hysteresis
0 °C to 9 °C
Heater hysteresis
10 °C
Blow-through control
work time: 0 - 90 sec.
pause: 1 - 60 min.
Controllable boiler extinguishing time
0 - 45 min.
Input power
fan: 100 VA / 230 V
heater: 100 VA / 230 V
Voltage AC
230 V, 50 Hz
Electrical protection
2 x 1,25 A
Relative air humidity
< 95 %
Protection class
IP 40
Insulation class
II
Ambient temperature
0 °C to + 40 °C
Software class
A
Operation type
fan: 1Y
heater: 1B
4.10. Technical data of the controller
12
Summary of Contents for Orligno 600
Page 1: ...ORLIGNO 600 INSTRUCTION MANUAL SERVICE MANUAL HOT AIR BLOWER...
Page 17: ...17 1 2 3...
Page 26: ...26 2 5 Dimensions...
Page 31: ...31...
Page 32: ......