19. Alarms
Menu contains history of maximum 20 alarms, that occured during controller’s work. Meanings of
code alarms is shown below:
Alarm codes and their meaning.
Code
Short description
Description
1
Processor’s overheating
Controller’s processor has been overheated. Improper
controller placement may be one of the reasons.
2
Lack of fl ame/fuel
Controller detected lack of fl ame in burner. Lack of fuel
or fl ame gone out may be one of the reasons.
3
Burner’s overheating
Burner’s temperature has exceeded maximum value
4
Boiler’s sensor short circuit
Controller detected short circuit. Damaged sensor or
connecting wire may be one of the reasons.
5
Boiler’s sensor break
Controller detected gape of boiler sensor. Damaged
sensor or conecting wire may be one of the reasons.
6
Burner’s sensor short circuit
Controller detected gape of sensor. Damaged sensor or
connecting wire may be one of the reasons.
7
Gape of burner’s sensor
Controller detected gape of sensor. Damaged sensor or
connecting wire may be one of the reasons
8
Boiler’s overheating
Boiler’s temperature has exceeded maximum value
9
Processor reset
Possible controller’s damage! Lack of power supply
43
Summary of Contents for ORLIGNO 100
Page 1: ...ORLIGNO 100 MANUAL AND SERVICE MANUAL...
Page 6: ...6 3 1 Dimensions 3 2 Boiler construction...
Page 7: ...7 3 3 Safety valve connection...
Page 12: ...12...
Page 23: ...23 Pic 5 Burner assembly Pic 6 Feeder assembly...
Page 24: ...5 4 Tank assembly 24...
Page 47: ...47...