24
WALL UNIT
25
Infinitely Expandable
W
ALL UNIT
Checking the location for installation.
2.
Check the type of wall to examine whether it can
withstand the weight of product.
Check the type and thickness of wall and the finish material.
y
Check the wall can withstand the weight of the product before installation.
y
You can use enclosed anchors and bolts, if the thickness of the finish material is 20mm or
y
less.
Never install the product to the wall of gypsum board.
y
Check the installation space.
Select the location suitable for the product size and install to maintain the horizontal and
y
the vertical position.
Leave some space between the product and wall or other structures. (Minimum 15cm)
y
If the product is installed in a closed space, it may be a cause of fire or malfunction for its
y
internal heat.
Fixing Anchor and Bolt
3.
Make sure to use specified accessory.
¹
Check the positions and intervals.
¹
If the hole positions are not accurate, the gap between MPDP sets can
be irregular.
Drill.a.hole.with.8mm.of.diameter.and.
80mm~100mm.of.depth.at.the.anchor.spot.
marked.at.the.wall.
.Fix.the.WALL.BRACKET.and.assemble.the.
washer.and.the.nut.
..Fasten.the.nut.securely.
Insert.the.attachment,.and.hit.it.to.insert.by.the.
hammer.
Attachment
Washer
Nut
Sleeve
Bolt
Drill
Insert.the.sleeve.along.the.bolt.
Clean.the.hole.
Insert.the.bolt.into.the.hole.
Hammer
WALL.BRACKET
Summary of Contents for MPDP