SYMPTOM 

POSSIBLE FAULT 

SOLUTION

Pump stationary, or 

runs very slowly 

No or low air pressure. 

Check the air line valve, regulator and quick coupler.

Faulty air motor. 

Check air motor mechanism. Check seals as required and 

replace any faulty parts. 

Blocked air inlet filter 

Change or clean the air inlet filter

Ice blocking air exhaust

Inspect for possible condensate in air filter or, if the pump 

has “raced”, that there is no leakage in the pipe work.

Foreign object jamming the movement of the central 

bar.

As above. Check for free movement and for foreign objects 

in piston valve etc.

Pump reciprocating but 

not delivering fluid.

No fluid

Check fluid level in drum/tank in relation to riser tube/outlet 

point.

Foot valve inoperative.

Check spring and valve for correct operation and seating. 

Check for foreign objects jammed in foot valve.

Piston valve or seals worn out.

Check for foreign objects in piston valve seat. Check seals 

for wear and damage.

Oil is coming out of the 

“leakage” hole in the 

outlet body 

Packing between air motor and pump is worn out or 

damaged. 

See “Service,  exchange of packings between air motor and 

pump tube”. 

Pump is running 

despite the outlet being 

closed 

Packing on the lower piston assembly is worn out or 

damaged.

See “Service to pump mechanism”. 

Dirt in the bottom valve or in the lower piston assem-

bly.

See “Service to pump mechanism”.

SYMPTOM 

TROLIG ORSAK

ÅTGÄRD

Pumpen går ej eller 

ingen vätska kommer.

Ej tillräckligt lufftryck.

Kontrollera luftventil, regulator och snabbkoppling.

Trasig luftmotor.

Kontrollera luftmotorn och dess tätningar och byt ut om 

nödvändigt.

Blockerat luftfilter.

Byt eller rengör filter.

Isbildning i ljuddämpare.

Kontrollera eventuell kondesering i luftfilter eller om pum

-

pen har rusat, kontrollera ev. läckage i rörledning.

Främmande föremål blockerar centralstångens 

rörelse.

Se ovan. Kontrollera att centralstången rör sig utan hinder 

och att inga partiklar eller föremål finns i kolven.

Pumpen går men  

levererar ingen vätska.

Ingen vätska

Kontrollera vätskenivå i förhållande till sugrör.

Bottenventil ej tät.

Kontrollera fjäderns rörelse och att ventilen tätar.

Kontrollera att inget skräp har fastnat i bottenventilen.

Kolv eller kolvtätningar utslitna.

Kontrollera skräp i kolvens kulsäte. Kontrollera tätningarna.

Olja läcker ut genom 

läckagehål i pumphus.

Tätningar mellan luftmotor och vätskedel är utslitna 

eller skadade.

Se “Byte av manschettpackning mellan luftmotor och 

pumprör”

Luft läcker ut genom 

ljuddämpare när 

pumpen står still.

Tätning i nedre kolv är utsliten eller skadad.

Se “Service Pumprör”

Smuts i bottenventil eller nedre kolv.

Se “Service Pumprör”

EN

SE

Summary of Contents for 22750

Page 1: ...MANUAL BRUKSANVISNING 1 Alentec Orion AB Grustagsv gen 4 SE 13840 lta SWEDEN info alentec se www alentec com Part No Art Nr R f 22750 22752 5 1 AIR OPERATED OIL PUMP TRYCKLUFTSDRIVEN OLJEPUMP 5 1 105...

Page 2: ...t 20 C and max air pressure 38 l min Air inlet thread 1 4 BSP F Fluid outlet thread 3 4 BSP M Fluid inlet 1 BSP F Noise level at 0 7 MPa 84 dB Drum adapter G 2 BSP 2 Included TEKNISKA DATA 22750 22752...

Page 3: ...il container by a separate small hose Always turn off the air pressure to the pump when the premises are unattended Den tryckluftsdrivna v tskepumpen har tv huvuddelar En dubbelverkande kolvmotor och...

Page 4: ...the same pressure rating as the corresponding working pressure of the system When starting up the system for the first time all valves and meters should Tag bort skyddsemballage och skyddspluggar fr n...

Page 5: ...otor B Foot valve to pump tube C All air motor screws 2 x 4 pcs D All connections to hose or pipe connection Do not overtighten skador b de p m tverk och p den person som eventuellt befinner sig framf...

Page 6: ...ings Pos 13 to get access to the U packings Pos 9 Push the U packings and their respective sleeves Pos 10 upwards and Pos 11 downwards out of the pump body F r din personliga s kerhet ska luftmotorn v...

Page 7: ...t is important to lubricate all parts and seals with Silicon grease before re assembling No other grease should be used Se de 2 f rsta punkterna under Byte av manschettpackning mellan luftmotor och pu...

Page 8: ...ite the outlet being closed Packing on the lower piston assembly is worn out or damaged See Service to pump mechanism Dirt in the bottom valve or in the lower piston assem bly See Service to pump mech...

Page 9: ...sleeve Undre styrning 11 1 Washer Bricka 12 2 Lock ring L sring 13 2 O ring O ring 36 1 Clamping pin R rpinne 17 1 Screw Skruv 28 2 Screw Skruv 34 2 Screw Skruv 33 2 Silencer Ljudd mpare 23 1 142 52...

Page 10: ...pin R rpinne 17 1 Piston complete Kolv komplett 20 1 Piston packing Kolvpackning 21 1 212 53 32 212 56 17 Foot valve complete Bottenventil komplett Complete kit Komplett kit 25 22 1 242 62 86 242 62...

Page 11: ...Alentec Orion AB Grustagsv gen 4 SE 13840 lta SWEDEN info alentec se www alentec com 11 GENERAL ALLM NT G N RALIT S SPARE PART KITS RESERVDELSSATSER...

Page 12: ...DIN EN 292 2 11 91 and has been declared in conformity with the EC Directive 2006 42 EEC Alentec Orion AB Grustagsv gen 4 SE 13840 lta Sverige deklarerar genom detta certifikat att de omn mnda utrust...

Reviews: