background image

Alentec & Orion AB

 Grustagsvägen 4, SE-13840, Älta, SWEDEN · [email protected] · www.alentec.com

6

SERVICE / SERVICE

For your personal safety disconnect the air motor from the air supply before 

any service is undertaken, with the exception for when testing a pump and 

great caution should be exercised.

All screws and threaded components are right handed unless otherwise 

indicated. 

Avoid damage to packings and all moving surfaces. When servicing the 

pump, all parts should be protected from dirt, especially the cylinder and the 

central bar. Keep the working area and tools clean!

Be very careful when dismantling and assembling the O-rings and seals. At 

the least suspicion that parts are damaged or worn out, these parts must 

be replaced. O-rings which are not elastic, have signs of wear or have been 

shaped after their grooves should always be replaced.

Clean and grease all surfaces with silicone grease or similar, especially all 

O-rings and moving surfaces before re-assembling. 

Use Kerosene or similar liquids for cleaning the parts. If a water-based fluid 

is used, all parts must be dried, immediately and carefully, directly after 

cleaning in order to avoid any corrosion.  

 

  

EXCHANGE OF PACKINGS BETWEEN AIR 
MOTOR AND PUMP TUBE 

 

Fasten the outlet housing of the pump into a vice with the pump in a 

horizontal position. Loosen the 4 lower screws (Pos 34) and pull off the air 

motor with the complete valve mechanism. Unscrew the pump tube with a 

strap wrench. Do not use a pipe wrench since this will damage the pump 

tube. Do not pull off the pump tube (Pos 19/27) completely. Only pull it 

enough to get access to knock out the clamping pin (Pos 17). Unscrew the 

piston rod (Pos 18/24). 

Pull the central bar (Pos 16) out through the outlet body. Inspect all working 

surfaces and replace it if necessary. 

Release the lock rings (Pos 13) to get access to the U-packings (Pos 9). 

Push the U-packings and their respective sleeves (Pos 10) upwards, and 

(Pos 11) downwards, out of the pump body. 

För din personliga säkerhet ska luftmotorn vara frånkopplad från 

tryckluftsnätet under allt servicearbete utom vid en ev. provkörning då stor 

försiktighet skall iakttas. 

Alla skruvar och gängade detaljer är högergängade om inte annat tydligt 

anges. 

Undvik repor och skador på tätningar och glidytor. Under allt arbete skall 

delarna skyddas från stoft och föroreningar. I synnerhet skall cylinderlopp 

och centralstången skyddas. Håll arbetsbänken och verktygen rena! 

Var mycket försiktig vid demontering och montering av O-ringar och 

manschetter. Vid minsta misstanke om förslitning eller skada i samband 

med isärtagning resp. återmontering skall de bytas. O-ringar som ej är 

elastiska, har slitskador eller formats efter sina spår skall alltid bytas.  

Rengör och fetta in alla tätnings- och glidytor med Silikon-fett eller 

motsvarande. I synnerhet skall alla O-ringar och tätningar smörjas in före 

återmontering. 

Använd helst varnolen eller liknande vätska vid rengörning av delar. Om 

vattenbaserad vätska används måste delarna torkas, omedelbart och 

noggrant direkt efter tvätt, för att förhindra att korrosion uppkommer.  

BYTE AV MANSCHETTPACKNING MELLAN 
LUFTMOTOR OCH PUMPRÖR 

Fäst pumpens utloppshus i ett skruvstycke med pumpröret vågrätt. Lossa de 

4 undre skruvarna (Pos 34) och drag bort hela luftmotorn med sin mekanism. 

Lossa pumpröret med en ”strap”-tång (bandtång). Används rörtång riskerar 

man att skada pumpröret.  Drag inte av pumpröret (Pos 19/27) helt utan 

endast så mycket att man kommer åt att slå bort stiftet (Pos 17). Gänga av 

kolvstången (Pos 18/24). 

Drag upp centralstången (Pos 16) genom utloppshuset. Inspektera alla 

tätningsytor med avseende på slitage och skador. 

För att byta manschetterna (Pos 9) lossas låsringarna (Pos 13). Tryck 

sedanmanschetterna med sina respektive styrningar (Pos 10) uppåt, och (Pos 

11) nedåt ut ur utloppshuset. 

SERVICE

SERVICE

EN

SE

Summary of Contents for 22750

Page 1: ...MANUAL BRUKSANVISNING 1 Alentec Orion AB Grustagsv gen 4 SE 13840 lta SWEDEN info alentec se www alentec com Part No Art Nr R f 22750 22752 5 1 AIR OPERATED OIL PUMP TRYCKLUFTSDRIVEN OLJEPUMP 5 1 105...

Page 2: ...t 20 C and max air pressure 38 l min Air inlet thread 1 4 BSP F Fluid outlet thread 3 4 BSP M Fluid inlet 1 BSP F Noise level at 0 7 MPa 84 dB Drum adapter G 2 BSP 2 Included TEKNISKA DATA 22750 22752...

Page 3: ...il container by a separate small hose Always turn off the air pressure to the pump when the premises are unattended Den tryckluftsdrivna v tskepumpen har tv huvuddelar En dubbelverkande kolvmotor och...

Page 4: ...the same pressure rating as the corresponding working pressure of the system When starting up the system for the first time all valves and meters should Tag bort skyddsemballage och skyddspluggar fr n...

Page 5: ...otor B Foot valve to pump tube C All air motor screws 2 x 4 pcs D All connections to hose or pipe connection Do not overtighten skador b de p m tverk och p den person som eventuellt befinner sig framf...

Page 6: ...ings Pos 13 to get access to the U packings Pos 9 Push the U packings and their respective sleeves Pos 10 upwards and Pos 11 downwards out of the pump body F r din personliga s kerhet ska luftmotorn v...

Page 7: ...t is important to lubricate all parts and seals with Silicon grease before re assembling No other grease should be used Se de 2 f rsta punkterna under Byte av manschettpackning mellan luftmotor och pu...

Page 8: ...ite the outlet being closed Packing on the lower piston assembly is worn out or damaged See Service to pump mechanism Dirt in the bottom valve or in the lower piston assem bly See Service to pump mech...

Page 9: ...sleeve Undre styrning 11 1 Washer Bricka 12 2 Lock ring L sring 13 2 O ring O ring 36 1 Clamping pin R rpinne 17 1 Screw Skruv 28 2 Screw Skruv 34 2 Screw Skruv 33 2 Silencer Ljudd mpare 23 1 142 52...

Page 10: ...pin R rpinne 17 1 Piston complete Kolv komplett 20 1 Piston packing Kolvpackning 21 1 212 53 32 212 56 17 Foot valve complete Bottenventil komplett Complete kit Komplett kit 25 22 1 242 62 86 242 62...

Page 11: ...Alentec Orion AB Grustagsv gen 4 SE 13840 lta SWEDEN info alentec se www alentec com 11 GENERAL ALLM NT G N RALIT S SPARE PART KITS RESERVDELSSATSER...

Page 12: ...DIN EN 292 2 11 91 and has been declared in conformity with the EC Directive 2006 42 EEC Alentec Orion AB Grustagsv gen 4 SE 13840 lta Sverige deklarerar genom detta certifikat att de omn mnda utrust...