6
105260 R. 12/21
Alentec & Orion AB · Grustagsvägen 4 · SE-138 40 · ÄLTA · Sweden · +8 747 67 00 · www.alentec.com
2021_12_15-12:00
EN
EN
• Optional kit is required for remote exhaust.
• Unscrew the 4 bolts and remove the standard muffler (pos. 1-10, pos.
1-12) in pump part drawing.
• Place the remote exhaust adaptor (pos. 1-41), (remember to install the
included o-ring on its housing, (1-40). Screw the four bolts (pos. 1-42)
previously removed.
• Connect a hose to the new exhaust port and install the muffler at the
end of the hose. Use a hose with the same diameter as the exhaust
port 3/4” NPT. (If the hose is more than 1.5 m (5 feet), consult your local
distributor or ALENTEC & ORION AB).
• Have a moat, a protective housing, etc. at the end of the hose.
WARNING
INSTALLATION
AIR EXHAUST DISPOSAL
RECOMMENDED INSTALLATION
The figure below shows the recommended configuration for the installation of a diaphragm pump.
Read the warnings and recommendations of the previous page before starting.
NON-METALLIC
Nº DESCRIPTION
Qty.
1
Bolt
4
2
Spring lock washer
4
3
Flat washer
4
4
Standard pipe flange
1
5
Gasket
1
6
Flat washer
4
7
Nut
4
REMOTE EXHAUST
ADAPTER KIT (SEE PUMP
PARTS DRAWING)
WARNING:
To ensure that the air supply is sufficient to meet the demand of the pump, the diameter of the pipe must be equal to the diameter
of the supply port of the pump. Choose auxiliary air treatment equipment and fittings with sufficient airflow to exceed the air consumption of
the pump. In addition, peripheral air treatment equipment must be installed as close as possible to the pump unit.
The use of a coupler to connect the hoses aids future operation and maintenance tasks.
AIR CONNECTION