100c
User Manual
12
ch
.
1
MICROSCOPE ARM SETUP
A video explanation of the microscope setup can be found at
http://www .orionwelders .com/
resources/orion-c-series-resources/
1 . Place the upper half of the microscope arm into the arm base .
2 . Install the rubber eyepiece covers .
3 . Insert the welding stylus into the stylus holder
under the microscope head then tighten the stylus
holder knob .
4 . Loosen the bolt in front of the microscope mount
to move the microscope head left and right .
5 . Loosen/tighten the allen on the microscope
arm to adjust the spring pressure . Turn the allen
clockwise if the arm does not hold the microscope
up . Turn the allen counter clockwise if the arm does
not allow the microscope to come down .
6 . Ensure the microscope cable is plugged into the microscope shutter
light ring (this is an RJ45 port at the bottom of the microscope head) .
7 . Plug the other end of the microscope cable into the “Microscope” port
on the back of the power supply .
ADJUST WELDING STYLUS POSITION
A video explanation of the steps below can be found at
http://www .orionwelders .com/
resources/orion-c-series-resources/
1 . Loosen the screws on either side of the stylus holder .
2 . Adjust the welding stylus to a 45-degree angle then slightly
tighten the screws just enough to hold the stylus in place at a
45-degree angle
3 . While looking through the microscope, slide the welding
stylus holder forward/backward until the tip of the stylus is
in the center of your focus .
4 . Now securely tighten the stylus holder screws .
5 .
4 .
3 .
2 .
1 .
2 .
45°