TAP-3120-M12 User’s Manual
39 ORing Industrial Networking Corp.
2) Green On: Power is on and functioning
normally.
ETH1(2) Link / ACT:
Orange ON/Blinking: 10 Mbps Ethernet
Green ON/Blinking: 100 Mbps Ethernet
WLAN Link/ACT: Green for WLAN 1 and Red for
WLAN 2
Fault indicator:
Red On: Ethernet link down or power down
Power Requirements
Power Input Voltage
Dual power inputs PWR1/2: 12 ~ 48VDC in M23
connector
Reverse Polarity Protection
Present
Power Consumption
8.3 Watts
Environmental
Operating Temperature
-20 to 70°C
Storage Temperature
-40 to 85°C
Operating Humidity
5% to 95%, non-condensing
Physical Characteristics
Dimensions (W x D x H)
125mm(W) x 65mm(D) x 196mm(H)
Weight
1015 g
Casing
IP-40 protection
Regulatory Approvals
EMI
FCC Part 15, CISPR (EN55022) class A, EN50155
(EN50121-3-2)
EMS
EN61000-4-2 (ESD), EN61000-4-3 (RS),
EN61000-4-4 (EFT), EN61000-4-5 (Surge),
EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
Shock
IEC60068-2-27, EN61373
Free Fall
IEC60068-2-32
Vibration
IEC60068-2-6, EN61373
Rail Traffic
EN50155
Cooling
EN60068-2-1
Dry Heat
EN60068-2-2
Safety
EN60950-1
Summary of Contents for Transporter TAP-3120-M12