5.9 Alerts
5.9.1 Fault Alarm
When any selected fault event happens, the Fault LED on the switch panel will light up and the
electric relay will signal at the same time. The following pages allow you to set up alert
conditions based on your needs for individual switch ports, including actions to be taken during
disconnection and power failure.
5.9.2 System Warning
SYSLOG Setting
SYSLOG is a protocol that allows a device to send event notification messages across IP
networks to event message collectors. It permits separation of the software that generates
messages from the system that stores them and the software that reports and analyzes them.
As Syslog messages are UDP-based, the sender and receiver will not be aware of it if the
packet is lost due to network disconnection and no UDP packet will be resent.