IDS-4312(+) Series User Manual
ORing Industrial Networking Corp
28
Alive Check
The serial device will send a TCP alive-check package in each
defined time interval (Alive Check) to remote host to check the
TCP connection. If the TCP connection is not alive, the
connection will be closed and the port will be freed.
0
means the
function is disabled which is the factory default value.
Connect on Startup
The TCP Client will build a TCP connection once the connected
serial device is started.
Connect on Any
Character
The TCP Client will build a TCP connection once the connected
serial device starts to send data.
UDP Mode
Compared to TCP communication, UDP is faster and more efficient as you can unicast or
multicast data from the serial device server to host computers, and the serial device can also
receive data from one or multiple host.
Label
Description
Listening Port
IP port for listening incoming messages.
Destination
Host
Begin / End
If there are more than one destination hosts, specify the IP
address range by inputting a value in destination host IP begin /
end fields. You can also auto scan the sending port number of
the device.