Gap Setting Roller
Gap setting roller is mounted on a swiveling bar. This swiveling bar is located
below the feed tray.
Note:
gap setting roller is a fixed roller. Do not make attempts to make it rotate, it
may get damaged
Gap between the freewheel roller and the gap setting roller determines the thickness
of paper that can pass through. There are two methods for adjusting this gap.
1. Course Tuning Method
For setting more than 1 mm, you have to rotate the swiveling bar on which the gap
setting roller is mounted. Loosen the Allen screws at the right hand side end (motor
side) of the swelling bar. Rotate the swelling bar to adjust the gap. Tighten the
screws. Use the Gap setting knob to fine the gap.
2. Fine Tuning Method
Rotate the gap setting knob provided. This will allow setting of + 0.5mm. When you
rotate the knob clockwise, gap reduces and when you rotate it Anti clockwise gap
increases. This setting should be used to fine tune the gap. Please
see Figure No.7
11
Summary of Contents for OCM 20
Page 12: ...12...