Method of control via Modbus protocol
−30−
Parameter R/W commands [I/O function (Remote I/O)]
Register address
Name
Setting range
Initial value Update
*1
Dec
Hex
4448
1160h NET-IN0 input function selection (upper)
0: Not used
1: FWD (START/STOP)
*2
2: REV (RUN/BRAKE)
*2
19: STOP-MODE (FWD/REV)
*2
20: MB-FREE
27: HMI
48: M0
49: M1
50: M2
48
C
4449
1161h NET-IN0 input function selection (lower)
4450
1162h NET-IN1 input function selection (upper)
49
4451
1163h NET-IN1 input function selection (lower)
4452
1164h NET-IN2 input function selection (upper)
50
4453
1165h NET-IN2 input function selection (lower)
4454
1166h NET-IN3 input function selection (upper)
1
4455
1167h NET-IN3 input function selection (lower)
4456
1168h NET-IN4 input function selection (upper)
2
4457
1169h NET-IN4 input function selection (lower)
4458
116Ah NET-IN5 input function selection (upper)
19
4459
116Bh NET-IN5 input function selection (lower)
4460
116Ch NET-IN6 input function selection (upper)
0
4461
116Dh NET-IN6 input function selection (lower)
4462
116Eh NET-IN7 input function selection (upper)
20
4463
116Fh NET-IN7 input function selection (lower)
4464
1170h NET-IN8 input function selection (upper)
0
4465
1171h NET-IN8 input function selection (lower)
4466
1172h NET-IN9 input function selection (upper)
0
4467
1173h NET-IN9 input function selection (lower)
4468
1174h NET-IN10 input function selection (upper)
0
4469
1175h NET-IN10 input function selection (lower)
4470
1176h NET-IN11 input function selection (upper)
0
4471
1177h NET-IN11 input function selection (lower)
4472
1178h NET-IN12 input function selection (upper)
0
4473
1179h NET-IN12 input function selection (lower)
4474
117Ah NET-IN13 input function selection (upper)
0
4475
117Bh NET-IN13 input function selection (lower)
4476
117Ch NET-IN14 input function selection (upper)
0
4477
117Dh NET-IN14 input function selection (lower)
4478
117Eh NET-IN15 input function selection (upper)
0
4479
117Fh NET-IN15 input function selection (lower)
*1
It indicates the timing for the data to update.
C: Update after executing configuration
*2
The parentheses ( ) will be applied when the "3-wire input mode" is selected with the "Operation input mode selection"
parameter.