background image

3.  Installation

Installation conditions

Install the motor and capacitor in a location that meets the following conditions. 

Using the motor and capacitor in a location that does not satisfy these conditions could damage it.

3.1 Installing the motor

Installation varies with the shape of the motor's output shaft.

1) Round shaft motor

Drill holes in the mounting plate and fasten the motor to the mounting plate with

screws, nuts, and washers. (The mounting screws are not provided.) Be sure that

no gaps are left between the motor and the surface of the mounting plate.

Note: Do not insert the motor into the mounting hole

at an angle or force it in, as this may scratch

the flange pilot section and damage the motor.

2) Pinion shaft motor

Drill holes in the mounting plate and fasten the gearhead (sold separately)

and the  motor to the mounting plate using the four screws provided with the

gearhead. Install the equipment so that no gaps are left between the motor

flange surface and the gearhead pilot section end surface. 

Refer to the gearhead operation manual for further details concerning

mounting.

(gearhed sold separately )

Note: Use the gearhead of the same type of pinion shaft as the motor.

3) Motor with a cooling fan

When installing a motor with a cooling fan onto a device, leave 10 mm or more behind the fan cover or open a ventilation hole so that

the cooling inlet on the back of the motor cover is not blocked .

3.2 Installing capacitors

Before installing the provided capacitor, check that the capacitor’s capacitance matches that stated on the motor

s name plate.

Use the screws specified below to install capacitor. (Screws not provided.)

Notes: 1    When installing the rectangular capacitor with the plastic foot,  tighten the screw to

a torque of  1

Nm (10 kgcm) or less to prevent damage to the mounting foot.

2

Install capacitor at least 10 cm away from the motor. If it is located closer, the life of

the capacitor will be shortened.

- Indoors (this product is designed and manufactured to be installed within another device)

- Ambient temperature: -10 

to +40

℃(

14

to

104 )

(avoid freezing)

- Not exposed to explosive, flammable, or corrosive gases

- Ambient humidity: 85% max. (avoid condensation)

- Not exposed to direct sunlight

- Not exposed to dust

- Not exposed to water or oil

- In a location with good heat ventilation

- Not exposed to continuous vibration or excessive impact

- 1,000 meters or less above sea level

Motor

Mounting Screws
(not provided)

Mounting
Plate

Mounting Screws

First number in motor

name

3

4

5

Screw size

M5

M5

M6

Tightening torque

2.5N

m(25

㎏㎝

)

2.5N

m(25

㎏㎝

)

3.0N

m(30

㎏㎝

)

Motor

Gearhead

Screws provided
with gearhead

Mounting
Plate

φ

4.3

Mounting feet equipped.

Use screws of 4mm in diameter to install the capacitor.

2

(.169DIA.)

˚F

˚F

Reviews: