MULTI-STORY RESIDENCE

is over 12 meters (40feet) long, install an alarm at each end. 

At the top of the first-to-second floor stairway.   

IMPORTANT! 

Specific requirements for Smoke Alarm installation vary from state to state. Check with your local Fire 

Brigade for current requirements in your area.   

See “Recommended Locations For Smoke Alarm” Diagram following. 

 

 

 

 

 

 

 

 

KEY:

 

Minimum required smoke alarm locations 

Recommended additional smoke alarm locations 

Smoke alarms with silence features recommended 

  for additional protection   

             

 

IMPORTANT SMOKE ALARM PLACEMENT AND EXCEPTION INFORMATION 

1. Install a smoke alarm as close to the center of the ceiling as possible. If this is not practical, mount no 

closer than 4 inches from a wall or corner. Also, if local codes allow, install smoke alarms on walls, 

between 4 and 12 inches from ceiling/wall intersections.   

2. Install a minimum of two smoke alarms in every home, no matter how small the home.   

3. Install a smoke alarm in each room that is divided by a partial wall (either coming down from the ceiling 

at least 8 inches, or coming up from the floor). 

4. Install a smoke alarm in lived-in attics or attics which house electrical equipment like furnaces, air 

conditioners, or heaters. 

   

DO NOT INSTALL SMOKE ALARMS 

 

1. Near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces, hot water 

heaters). Use specialized smoke alarm with unwanted alarm control for this areas. 

2. In areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at 

0.9M(3ft)

0.9M(3ft)

ANYWHERE

IN THIS AREA

HORIZONTAL DISTANCE

 

                  FROM PEAK

 

DINING ROOM

LIVING ROOM

BEDROOM

BEDROOM

KITCHEN

MOBILE HOME

SINGLE-STORY RESIDENCE,APARTMENT,

1

0

C

M

(4

'')

1

0

C

M

(4

'')

CEILING

BEST HERE    NEVER HERE

ACCEPTABLE HERE

MIN

IMUM

MA

X

IMU

M

SIDEWALL

MINIMUM

10CM(4'')

Summary of Contents for VST-IS5981

Page 1: ...connector for easy installation Fitting and battery tamper resist feature Inter connectable up to 40 units Alarm and AC power supply indicator Extra loud alarm sound over 85 dB Low battery warning ind...

Page 2: ...or indoor noise sound sleepers drug or alcohol usage the hard of hearing etc If you suspect that this smoke alarm may not alert a household member install and maintain specialty smoke alarms Househol...

Page 3: ...moke alarms on walls between 4 and 12 inches from ceiling wall intersections 2 Install a minimum of two smoke alarms in every home no matter how small the home 3 Install a smoke alarm in each room tha...

Page 4: ...lectrical supply is isolated 1 From back of smoke alarm remove the mounting plate by turning it counterclockwise To later engage tamper resist feature twist out and set aside one of the pins molded in...

Page 5: ...OKE ALARM Once the smoke alarm has been installed a small GREEN indicator light LED should be visible through the alarm grill indicating that AC supply is healthy A RED indicator light LED should also...

Page 6: ...nterclockwise to detach it from the mounting plate 3 Gently pull down smoke alarm 4 Remove battery from the compartment 5 Insert a new 9 volt battery to connector NOTE POLARITY OF CONNECTIONS Ensure t...

Page 7: ...tice fire safety rules and prevent hazardous situations TROUBLESHOOTING WARNING DO NOT disconnect battery to quiet an unwanted alarm This will remove your protection Fan the air or open a window to re...

Reviews: