Wiring Connection :
Circuit Description
1. Electrify Status For The First Time
As the icemaker is properly installed.
switch on the water tap, let the water trough full
(reach on the level),
then
turn the Power switch to the ON position
on the panel. The
icemaker will start working automatically
In this status, the time is fixed about 3 minutes. This function is also helpful to protect the
compressor avoiding restart within 3 minutes.
At this status, the
White, Green, Yellow and Red
LEDs are light together.
2. Ice-making Status
The compressor, motor fan and pump are powered on. The hot gas solenoid valve is powered off.
When this green LED is lit, the unit is working in the ice making mode controlled by a temperature
probe on the evaporator. When the green LED is flashing, the unit is working in the ice making
mode controlled by a fixed timer.
The fan motor is also controlled by a condenser sensor. When the ambient temperature is too lower,
the motor fan stop working for good condensation to refrigerant.
3. Ice Harvest Status
The pump is powered off. The hot gas solenoid valve, compressor and motor fan is powered on.