Installation Manual:

 

AdvanTex

®

 AX20-RT Treatment Units

NIM-ATX-AXRT-1

Rev. 1.0, 1/10

© 2010 Orenco Systems

®

 Inc.

14

Step 11: Test System Function

Once power is connected to the control panel, follow these steps 

to prepare the system for operation. 

IMPORTANT: 

Before using a generator to operate a pump, 

contact Orenco or your Dealer to make sure it can supply suffi-

cient starting amperage.

NOTE: 

When testing pumps, always make sure there is enough 

water in the unit to safely run the pumps.

Step 11a: 

Open the manifold valve and the lateral ball valves 

and then toggle the “AUTO/OFF/MAN” switch for the recirc 

pump to “MAN” for 5-10 seconds to flush any debris out of 

the manifold and laterals. Close the lateral ball valves. With the 

recirc pump still in “MAN,” remove several orifice shields and 

measure squirt height. Squirt height should measure between 

3-5 ft (0.9-1.5 m). Windy conditions will cause a lower squirt 

height. When finished, return the “AUTO/OFF/MAN” switch to 

“AUTO.”

NOTE: 

If the desired squirt height is not achieved or the unit 

does not pressurize, check for debris, breaks, or closed valves. 

Also verify that the pump is receiving sufficient power. If the unit 

still does not pressurize correctly, contact your Dealer or Orenco 

for technical assistance.

Step 11b: 

Place the panel in Test Mode. Check the function of 

the recirc pump floats by lifting the low-level, mid-level, and 

high-level float in turn and verifying that the pump cycles on and 

off for each. If the unit is not equipped with a discharge pump, 

take the control panel out of Test Mode at this time. 

Step 11c: 

If the unit has a discharge pump, make sure there is 

enough water on the discharge side of the tank baffle for the 

pump to run. Make sure the panel is in Test Mode. Check the 

function of the discharge pump floats by lifting the low-level, 

mid-level, and high-level float in turn and verifying that the 

pump cycles on and off for each. When you are finished, take the 

control panel out of Test Mode.

Step 11d: 

Close and bolt down the AX20-RT unit lid when you 

are finished. 

11a

Measure squirt height.

Open the manifold valve and lateral valves.

Manifold  

valve

Lateral ball valve  

(six total)

11a

Summary of Contents for AdvanTex AX20-RT

Page 1: ...AdvanTex AX20 RT Treatment Systems An illustrated guide to installing an Orenco AdvanTex AX20 RT Treatment System 800 348 9843 541 459 4449 www orenco com www vericomm net Orenco Systems Incorporated...

Page 2: ...ew before shipping If this system or any of its components possesses flaws that would inhibit its proper func tioning please contact your authorized AdvanTex Dealer The Dealer can also provide repair...

Page 3: ...sting primary tank must have an at grade access with a securable and removable lid If it doesn t an at grade access must be installed onto the primary tank and be made watertight The primary tank must...

Page 4: ...ayer passes through a Biotube effluent filter and is discharged by gravity to the recirculating treatment tank portion of the AX20 RT unit which contains a Biotube Pump Package The Biotube Pump Packag...

Page 5: ...ans or with plans of limited detail contact your local Dealer or Orenco for design assistance Determine and sketch the exact positions of the primary tank and AX20 RT unit on the site Account for curr...

Page 6: ...emember that you need the correct depth for a consistent slope of 1 8 in per foot 10 mm per meter or 1 from the septic tank outlet to the inlet of the AX20 RT Step 2c Make sure the bottom of the excav...

Page 7: ...m into the riser because structural damage to the tank may occur The inlet and outlet pipe into the tank needs to be turned up or plugged to allow the tank to be filled CAUTION Check the tank manufact...

Page 8: ...the unit is excavated and after a com pacted bed of aggregate or pea gravel if necessary is laid Step 5c Make sure the bottom of the excavation is stable and free of debris especially rocks and other...

Page 9: ...Apply a in 19 mm bead of SS115 or SS140 adhesive down the length of each flange 4 Slide the flanges under the AX20 RT unit and then lower the unit onto the flanges Allow the adhesive to set before mo...

Page 10: ...ill to minimize settlement and provide sup port for the walls of the unit Step 7c After the first layer of backfill is complete fill the tank with water to just above the midseam flange on both sides...

Page 11: ...AX20 RT unit Be sure the vent line is sloped to drain towards the unit and that the passive air vent is within 20 ft 6 m of the unit After installation the top of the passive air vent should be a mini...

Page 12: ...nclude the following items a Incoming power to the panel One or more circuits may be required depending upon the number of pumps and local electrical codes b Incoming phone line to the panel for VeriC...

Page 13: ...isabled Local audible and visual alarms are activated as alarm conditions occur System Data Logs are suspended and Timer cycles are shortened Step 10f Familiarize yourself with the floats on the syste...

Page 14: ...Comm Monitoring System A red LED Modem Activity component should illuminate indicat ing that the controller has established communication with the host This may take a few minutes Once the communicati...

Page 15: ...desired squirt height is not achieved or the unit does not pressurize check for debris breaks or closed valves Also verify that the pump is receiving sufficient power If the unit still does not pressu...

Page 16: ...non cohesive soils with high seasonal water tables use in crushed rock as the backfill material The top of the AX20 RT lid should sit 2 in 50 mm above final grade IMPORTANT After backfilling call the...

Page 17: ...Installation Manual AdvanTex AX20 RT Treatment Units NIM ATX AXRT 1 Rev 1 0 1 10 2010 Orenco Systems Inc 16 Notes 17...

Page 18: ...Installation Manual AdvanTex AX20 RT Treatment Units NIM ATX AXRT 1 Rev 1 0 1 10 2010 Orenco Systems Inc Notes 17...

Page 19: ...Installation Manual AdvanTex AX20 RT Treatment Units NIM ATX AXRT 1 Rev 1 0 1 10 2010 Orenco Systems Inc Notes 18...

Page 20: ...ystems Residential Applications 800 348 9843 541 459 4449 www orenco com www vericomm net Orenco Systems Incorporated Changing theWay the World DoesWastewater N S F ANSI STANDARD 4 0 NSF AdvanTex Trea...

Reviews: