background image

5

E

N

G

L

I

S

H

CAUTION—Wood Floors, Soft (Vinyl, Asphalt Tile, etc.) Floor
Surfaces and Polished Floor Finishes

Use floor and floor finish manufacturer’s recommended methods of
cleaning. The metal strip on the base of the cleaner could be damaged
if used on concrete or abrasive surfaces, and, therefore, cause damage
to wood floors, soft (vinyl, asphalt tile, etc.) floor surfaces and polished
floor finishes. The roller brush may also scuff very soft finishes. Do not
operate the unit while in the upright and locked position. Do not let the
unit run while in any one stationary position for any period of time. Keep
the unit moving while in operation.  

Celoc

®

Hypo-Allergenic Filter System

The Celoc SMMSP outer bag of your vacuum cleaner is a high filtration
medical material designed to filter the smallest of dust particles. For
peak performance, the inside of the outer bag must be cleaned. Turned
inside out, vacuum the inside of the outer bag or hand wash with warm
water, and allow to air dry. The Celoc layered disposable inner dust bag
must be replaced once a month even if it is not full. Change it more
often if it is used in extremely dirty areas. Increase the cleaning power
of your vacuum by changing the bag often.

To Replace Filter Dust Bag

WARNING: Unplug cord from electrical
outlet before servicing.

BAG REMOVAL:

fig. 6

Unzip outer bag completely.

fig. 7

Pull bag cardboard collar to release bag dock door from
connector. Bag dock door will hinge downward.

fig. 8

Gently pull bag cardboard collar upward out of the bag dock.
Dust seal will close automatically.

BAG INSTALLATION:

fig. 9

Slide the cardboard collar completely into bag dock door.

fig. 10

Firmly push bag dock door with both thumbs on indication point
until it snaps.

How to Replace a Worn Belt

WARNING: Unplug cord from electrical
outlet before servicing.

fig. 11

Remove the replacement belt from the storage channel.

fig. 12 

Remove the door by removing the hold down screw located on
side of power head.

fig. 13

Slide the door forward by prying open with a screwdriver or coin.

fig. 14

Remove the belt from the brush roll pulley and motor drive shaft.

fig. 15

Loop the new belt over the motor drive shaft. Place the opposite
end of the belt on the brush roll pulley. Rotate the brush roll
three (3) complete revolutions to ensure that no part of the belt
is overhanging the end of the motor drive shaft.

fig. 13

Replace the door by sliding it into the groove at the bottom of
the housing.

fig. 12

Replace the hold down screw and tighten.

To Adjust or Replace Brush

WARNING: Unplug cord from electrical
outlet before servicing.

fig. 16

To determine if the brush is worn, place a firm straight edge
across the nozzle opening. If brush bristles do not extend
beyond baseplate, brush should be adjusted.

fig. 17

Remove the baseplate by removing 5 screws. 

fig. 18

Remove the belt and brush roll from the housing.

fig. 19

Rotate both bearing assemblies at ends of brush roll to show

"OLD"

and replace in the holding channels in the housing. 

NOTE:

The bearing assembly setting marked 

"OLD"

has no ridges on

the top of the assembly. The one marked 

"NEW"

has several ridges.

When rotating bearings, make sure both bearing assembly settings are
the same and face up when replacing the brush roll.

fig. 16

Reassemble the belt and the baseplate and check bristle height
above baseplate at each end of brush.

If a previous adjustment has already been made and bristle height does
not extend above baseplate, a new brush assembly should be ordered.

IMPORTANT: Unless the brush is worn as indicated above, both
bearings must be in the “NEW” position. When rotating, both
bearings must be in the “OLD” position. Unmatched settings will
cause damage to your machine.

Using An Oreck Fresh Air

®

Tab

fig. 20

Your ORECK XL vacuum cleaner has a special Oreck Fresh
Air

®

tab pocket. This light-colored pocket is located inside the

outer bag in the area where the disposable paper bag attaches
to the intake tube. Insert tablet in pocket if desired.

Bulb Replacement

WARNING: Unplug cord from electrical
outlet before servicing.

fig. 21

Remove lamp housing by removing two (2) screws in the the
top of the lamp housing. Pull burned out bulb from holder and
replace with new bulb. Use only Oreck replacement parts.
Replace lamp housing by replacing two screws in the top of the
lamp housing.

Stuffing or Blockage

IMPORTANT:

On plush and new carpets, stuffing may occur inside the

the intake tube and the lower tube assembly. This is due to excessive fuzz
and loose cuttings in the carpet. Stuffing could occur for the first few
cleanings until all the loose material is removed. Due to the high efficiency
of the cleaner, many older carpets will cause stuffing when the cleaner is
first used on them. If your vacuum cleaner does not pick up properly, or
makes unusual noise and the outer bag does not fluff up or balloon open,
follow these steps:

WARNING: Unplug cord from electrical
outlet before servicing.

fig. 22

Check for blockage at the mouth of the intake opening. If there
is blockage, remove it with long-nose pliers, a screwdriver or
coat hanger. If you can not reach the blockage, remove
baseplate 

(fig. 23)

.

fig. 24

If the blockage is not at the base, remove lower tube. Unhook
retainer spring, releasing bottom of bag. 

fig. 25

Twist lower collar counterclockwise to slide up. Pull tube out of
base. 

fig. 26

Check for blockage. If blockage is in the tube, remove with a
coat hanger.

fig. 27

If tube is not blocked, look into fan housing. Remove debris
with long-nose pliers, a screwdriver or coat hanger.

fig. 25

To reassemble, check O-ring on tube, and replace if damaged.
Vacuum will not operate properly without the tube O-ring. Slide
O-ring to approximately 2" from base of tube. Replace tube by
first lining up slot at base of tube with inner tab inside fan
housing. Then reinsert tube and push down until the tube is
seated. Make sure O-ring is in place against fan housing
opening. Replace and tighten collar until collar locking tabs are
locked in place. 

fig. 28

Make sure collar is not cross threaded on housing. Reattach
bag spring 

(fig. 24)

.

fig. 29

Many times blockage occurs due to a full dust bag causing dirt to
back down the air flow system. When that happens, the
blockage will be at the top of the system, starting in the area
where the dust bag connects to the connector assembly.

NOTE: 

If the above actions do not correct the problem, contact an

Oreck authorized service center or call the customer service center.

US: 1-800-989-3535  Canada: 1-888-676-7325

Summary of Contents for Simply Amazing U4070H2

Page 1: ...ions Trouble Diagnosis Accessories E N G L I S H F R A N A I S GUIDE D UTILISATION PAGE 6 E S P A O L GUIA DEL USUARIO PAGE 11 USA 1 800 989 4244 CANADA 1 800 393 8801 VISIT ONE OF OUR OVER 450 STORE...

Page 2: ...ique Anillo t rico 29 Connector Deflector Opening Ouverture du connecteur d flecteur Abertura del deflector de la conexi n 26 27 Fan Housing Bo tier du ventilateur Bastidor del ventilador Tube Tubo 7...

Page 3: ...THIS VACUUM CLEANER WARNING To reduce the risk of fire electric shock or injury IMPORTANT SAFETY INSTRUCTIONS Do not leave appliance unattended when plugged in Unplug from outlet when not in use and b...

Page 4: ...grant any other warranty obligation with the sale of this product Oreck s limited warranty is valid only if you retain proof of purchase from Oreck or an Oreck Authorized Retail Dealer for this produc...

Page 5: ...int string or hair from revolving brush Wipe the outside of the cleaner with a damp cloth Also clean the connector deflector assembly area base of cleaner and fan housing area If there is dust in the...

Page 6: ...ings make sure both bearing assembly settings are the same and face up when replacing the brush roll fig 16 Reassemble the belt and the baseplate and check bristle height above baseplate at each end o...

Page 7: ...s probl mes avec votre appareil ORECK vous pouvez appeler le service la client le ORECK au US 1 800 989 3535 Canada 1 888 676 7325 Veuillez indiquer le num ro de mod le et le num ro de s rie code appa...

Page 8: ...tre applicable pour vous Cette garantie vous donne des droits l gaux sp cifiques et vous pouvez avoir d autres droits qui varient d une province l autre Lorsque vous utilisez un appareil lectrom nager...

Page 9: ...es comme suit 1 Section sup rieure du manche 2 Tube inf rieur 3 T te motoris e 4 Sac ext rieur 5 Sac poussi res en papier filtre 6 Cordon d alimentation 7 Ressort de retenue 8 Barre de tension du sac...

Page 10: ...ue ORECK ne feront pas fonctionner correctement le balai tournant et peuvent cr er une r sistance capable d endommager le moteur et les paliers du balai L utilisation d une courroie ne portant pas la...

Page 11: ...e l ampoule puis le bo tier de l ampoule Retirez l ampoule br l e de son r ceptacle et remplacez la par une neuve Utilisez seulement les pi ces de rechange d Oreck Replacez le bo tier de l ampoule pui...

Page 12: ...servicio a clientes de ORECK al US 1 800 989 3535 Canada 1 888 676 7325 Por favor especifique el n mero de modelo y el n mero de serie c digo el cual se puede encontrar en la placa de datos en la part...

Page 13: ...esidencial no para la reventa a Oreck o un minorista autorizado de Oreck Oreck reparar o reemplazar gratuitamente al comprador original cualquier pieza que resulte defectuosa en los materiales o la fa...

Page 14: ...ra las piezas se han numerado como sigue 1 Secci n del asa superior 2 Tubo inferior 3 Cabeza motriz 4 Bolsa exterior 5 Bolsa para polvo con filtro de papel 6 Cord n de alimentaci n 7 Resorte retenedor...

Page 15: ...reas que no sean de ORECK se anular la garant a Lubricaci n Los cojinetes del motor de la aspiradora se lubrican y sellan en la f brica No se requiere lubricaci n adicional Cuidados generales de la as...

Page 16: ...de la l mpara Jale la bombilla quemada de su soporte y reempl cela con la nueva bombilla Utilice solamente las piezas de recambio de Oreck Regrese a su lugar el bastidor de la l mpara colocando nuevam...

Reviews: