3. Loosen the saw blade nut (7) using the ring spanner SW 22 (left-handed
thread).
4. Remove the saw blade nut and the saw blade (if mounted) from the shaft.
5. Clean the saw blade shaft, the contact surface of the clamp and the
surrounding using a brush.
The clamping plate (8) must not be removed.
Cleaning the saw
blade surrounding
Note
8