INSTRUCTIONS FOR USE
OM 602RS
|
53
6.1.3a
External input function selection
6.1.3b
Selection of function “HOLD”
CHANNE.
SERVIC.
OUTPUT.
CLEAR
EXT. IN.
CONFIG.
KEYS
INPUTS
EXT. 2
EXT. 1
M. HOLD
EXT. 3
OFF
CL. M.M.
CL. TAR.
TARE
B. PASS.
LOCK. K.
HOLD
EXT. IN.
External input function
selection
OFF
Input is off
HOLD
Activation of HOLD
LOCK K.
Locking keys on the
instrument
B. PASS.
Activation of locking
access into programming
menu LIGHT/PROFI
TARE
Tare activation
CL. TAR.
Tare resetting
CL. M.M.
Resetting
min/max value
-
DEF
EXT. 1 >
HOLD
-
DEF
EXT. 2 >
LOCK. K.
-
DEF
EXT. 3 >
TARE
CHANNE.
SERVIC.
OUTPUT.
CLEAR
EXT. IN.
CONFIG.
KEYS
INPUTS
EXT. 2
EXT. 1
M. HOLD
EXT. 3
DISPL.
ALL
D.+A.O.+L.
DIS.+A.O.
M. MOLD
Selection of function
“HOLD”
DISPL.
“HOLD” locks only the
value displayed
DIS.+A.O.
“HOLD” locks the value
displayed and on AO
D.+A.O.+L.
“HOLD” locks the value
displayed, on AO and
limit evaluation
ALL
“HOLD” locks the entire
instrument
Setting procedure is identical for EXT. 2 and EXT. 3
*
6
profi
profi
SETTING
Summary of Contents for OM 602RS
Page 1: ...OM 602RS 6 DIGIT PROGRAMABLE INSTRUMENT RS 232 RS 485 GUARANTEE Y E A R S ...
Page 7: ...INSTRUCTIONS FOR USE OM 602RS 7 ...
Page 31: ...INSTRUCTIONS FOR USE OM 602RS 31 5 light light SETTING ...
Page 39: ...INSTRUCTIONS FOR USE OM 602RS 39 5 light light SETTING ...
Page 41: ...INSTRUCTIONS FOR USE OM 602RS 41 6 profi profi SETTING ...
Page 57: ...INSTRUCTIONS FOR USE OM 602RS 57 6 profi profi SETTING ...
Page 71: ...INSTRUCTIONS FOR USE OM 602RS 71 6 profi profi SETTING ...
Page 75: ...INSTRUCTIONS FOR USE OM 602RS 75 6 profi profi SETTING ...
Page 83: ...INSTRUCTIONS FOR USE OM 602RS 83 11 TECHNICAL DATA PI Primary insulation DI Double insulation ...
Page 86: ...86 INSTRUCTIONS FOR USE OM 602RS NOTE ...