50
|
INSTRUCTIONS FOR USE
OM 602RS
6.1.2j
Setting innitial two-symbol sequence
Protocol “UNIVERSAL”
6.1.2k
Seting the instrument address
Protocol “UNIVERSAL”
SIGNUM
DATA
CHANNE.
SERVIC.
OUTPUT.
CLEAR
EXT. IN.
CONFIG.
KEYS
INPUTS
BAUD
PROT.
STOP
START
ADDR.
MOD T.O.
REQUES.
2
TIMEOU.
START.2
START.1
START
Setting innitial two-
symbol sequence
START.1
Setting the first
intrductory symbol
- set directly in ASCII code
- range: 1…127
-
DEF
= 2
START.2
Setting the second
introductory symbol
- set directly in ASCII code
- range: 0…127
- if set to “0”, it will not be used
-
DEF
= 0
AD. POS.
TIMEOU.
SIGNUM
DATA
CHANNE.
SERVIC.
OUTPUT.
CLEAR
EXT. IN.
CONFIG.
KEYS
INPUTS
BAUD
PROT.
STOP
ADDR.
START
MOD T.O.
REQUES.
0
ADR. 2
ADR. 1
ADDR.
Setting the instrument
address
- either address in universal protocol or one
(or two) symbols of fixed value
AD. POS.
Setting the address
position
- Position of the address and other symbols
which have to have a set value. If set to 0,
the block will not be taken into account.
The block can be anywhere in the
message.
- range: 0…245
-
DEF
= 0
ADR. 1
First address symbol
- set directly in ASCII code
- range: 0…127
-
DEF
= 48
ADR. 2
Second address symbol
- set directly in ASCII code
- range: 0…127
- if set to “0”, it will not be used
-
DEF
= 49
6
profi
profi
SETTING
Summary of Contents for OM 602RS
Page 1: ...OM 602RS 6 DIGIT PROGRAMABLE INSTRUMENT RS 232 RS 485 GUARANTEE Y E A R S ...
Page 7: ...INSTRUCTIONS FOR USE OM 602RS 7 ...
Page 31: ...INSTRUCTIONS FOR USE OM 602RS 31 5 light light SETTING ...
Page 39: ...INSTRUCTIONS FOR USE OM 602RS 39 5 light light SETTING ...
Page 41: ...INSTRUCTIONS FOR USE OM 602RS 41 6 profi profi SETTING ...
Page 57: ...INSTRUCTIONS FOR USE OM 602RS 57 6 profi profi SETTING ...
Page 71: ...INSTRUCTIONS FOR USE OM 602RS 71 6 profi profi SETTING ...
Page 75: ...INSTRUCTIONS FOR USE OM 602RS 75 6 profi profi SETTING ...
Page 83: ...INSTRUCTIONS FOR USE OM 602RS 83 11 TECHNICAL DATA PI Primary insulation DI Double insulation ...
Page 86: ...86 INSTRUCTIONS FOR USE OM 602RS NOTE ...