Page 1: ...HTSC F02 In Line Optic Splice Closure Installation Guide...

Page 2: ...1 NOTES 1 Please read the user s guide before installation 2 Please pay attention while sealing the cable ports the inappropriate installation would affect the performance...

Page 3: ...ral introduction Page 3 2 Basic structure and configuration Page 3 3 Product illustration Page 3 4 Preparation for installation Page 4 5 Application Page 6 6 FOSC inspecting and testing items Page 6 7...

Page 4: ...perfect communication equipment and to ensure every customer has best quality of goods 2 Basic structure and configuration 2 1 Dimension and capacity Outside dimension LxWxH mm 179x72x26 Weight w o pa...

Page 5: ...stallation 4 2 1 Stripping the cable in 60mm length 4 2 2 Cut the reinforced core CSM Notice Be sure not to damage the fiber If the fibers are damaged cut if off and stripping the new fibers 4 3 Insta...

Page 6: ...l are spliced and then fix on the slot 4 5 Routing the fibers The diameter of the bending radius should be more than 30mm 4 6 Sealing the Closure 4 6 1 Routing of optical fiber should be neat in optic...

Page 7: ...outine test Before leaving factory Type test Package Each small package contains one fiber optic splice closure together with its accessories tools installation manual and packing list full At least 3...

Page 8: ...en observed for 24 hours there should be no change of air pressure Re sealing performance After reopening and resealing according to the stipulated operation procedures the injected air pressure is 10...

Page 9: ...n procedures immerse it in clean water of normal temperature in 1 5m depth for 24 hours there should be no breakdown or arc over between the metallic components of the FOSC between metallic components...