background image

 7 

Fiber storage 
device   

The fibers reserved are to be winded in fiber optic 
splice tray (FOST), the length of fibers housed in 
FOST is >1.6m, the curved radius is >30mm. During 
the installation and maintenance, there should be 
no attenuation on fibers.     

At  least  3  sets 
sampled each time 
 

Electrical 
jointing 
device 

Inside FOSC: metallic components of fiber cables 
has the functions of electrical putting through, 
earthing connection and disconnecting. It is 
possible to install earthing deriving device outside 
the housing   

Sealing 
performance 

After sealing according to the stipulated operation 
procedures, the injected air pressure is 
100KPa±5Kpa, when immersed in clean water of 
normal temperature for 15 minutes, there should 
be no air bubbles, then observed for 24 hours, 
there should be no change of air pressure. 

Re-sealing 
performance 

After reopening and resealing according to the 
stipulated operation procedures, the injected air 
pressure is 100KPa±5Kpa, when immersed in clean 
water of normal temperature for 15 minutes, there 
should be no air bubbles, then observed for 24 
hours, there should be no change of air pressure. 

Pull 

Bearing pull is 

 800N at axle orientation, there 

should be no breakage on the housing. 

Punching 

Bearing pressure of 2000N/10cm for 1 minutes, 
there should be no breakage on the housing 

Impact 

Bearing impact energy of 1

6N•m, 3 

times of 

impacts there should be not breakage on the 
housing 

Bending   

The spot between the FOSC and seal fitting can 
bear bending tension of 150N at bending angle of 
±45

0

 for 10 circles, there should be no breakage on 

the housing 

 
 
 
 

 

Torsion   

Bearing 

torsion 50N•m, 10 circle at torsion 

angle±90

0,   

There should be no breakage on the housing. 

Summary of Contents for HTSC-F02

Page 1: ...HTSC F02 In Line Optic Splice Closure Installation Guide...

Page 2: ...1 NOTES 1 Please read the user s guide before installation 2 Please pay attention while sealing the cable ports the inappropriate installation would affect the performance...

Page 3: ...ral introduction Page 3 2 Basic structure and configuration Page 3 3 Product illustration Page 3 4 Preparation for installation Page 4 5 Application Page 6 6 FOSC inspecting and testing items Page 6 7...

Page 4: ...perfect communication equipment and to ensure every customer has best quality of goods 2 Basic structure and configuration 2 1 Dimension and capacity Outside dimension LxWxH mm 179x72x26 Weight w o pa...

Page 5: ...stallation 4 2 1 Stripping the cable in 60mm length 4 2 2 Cut the reinforced core CSM Notice Be sure not to damage the fiber If the fibers are damaged cut if off and stripping the new fibers 4 3 Insta...

Page 6: ...l are spliced and then fix on the slot 4 5 Routing the fibers The diameter of the bending radius should be more than 30mm 4 6 Sealing the Closure 4 6 1 Routing of optical fiber should be neat in optic...

Page 7: ...outine test Before leaving factory Type test Package Each small package contains one fiber optic splice closure together with its accessories tools installation manual and packing list full At least 3...

Page 8: ...en observed for 24 hours there should be no change of air pressure Re sealing performance After reopening and resealing according to the stipulated operation procedures the injected air pressure is 10...

Page 9: ...n procedures immerse it in clean water of normal temperature in 1 5m depth for 24 hours there should be no breakdown or arc over between the metallic components of the FOSC between metallic components...

Reviews: