background image

 6 

4.7

 

The installation of the Body 

4.7.1

 

Put the Cover and the Bottom in alignment. 

4.7.2

 

Screw the screws with wrench. 

 

5.

 

Application 

Wall mounting application 

 

6. FOSC inspecting and testing items 

Inspecting   
item 

Technical Requirements 

Inspecting type 
Routine test 
(Before leaving 
factory) 

Type test 

Package 

Each small package contains one fiber optic splice 
closure, together with its accessories, tools, 
installation manual and packing list.   

full 

At least 3 sets 
sampled each 
time 
 

Appearance 

Intact in shape, no burrs, bubbles, chaps, pores, 
warps, impurities and other defects, all background 
colors should be even and continual. 

Sign 

There is a clear sign on the housing, such as name 
and model of the product, etc.   

Summary of Contents for HTSC-F02

Page 1: ...HTSC F02 In Line Optic Splice Closure Installation Guide...

Page 2: ...1 NOTES 1 Please read the user s guide before installation 2 Please pay attention while sealing the cable ports the inappropriate installation would affect the performance...

Page 3: ...ral introduction Page 3 2 Basic structure and configuration Page 3 3 Product illustration Page 3 4 Preparation for installation Page 4 5 Application Page 6 6 FOSC inspecting and testing items Page 6 7...

Page 4: ...perfect communication equipment and to ensure every customer has best quality of goods 2 Basic structure and configuration 2 1 Dimension and capacity Outside dimension LxWxH mm 179x72x26 Weight w o pa...

Page 5: ...stallation 4 2 1 Stripping the cable in 60mm length 4 2 2 Cut the reinforced core CSM Notice Be sure not to damage the fiber If the fibers are damaged cut if off and stripping the new fibers 4 3 Insta...

Page 6: ...l are spliced and then fix on the slot 4 5 Routing the fibers The diameter of the bending radius should be more than 30mm 4 6 Sealing the Closure 4 6 1 Routing of optical fiber should be neat in optic...

Page 7: ...outine test Before leaving factory Type test Package Each small package contains one fiber optic splice closure together with its accessories tools installation manual and packing list full At least 3...

Page 8: ...en observed for 24 hours there should be no change of air pressure Re sealing performance After reopening and resealing according to the stipulated operation procedures the injected air pressure is 10...

Page 9: ...n procedures immerse it in clean water of normal temperature in 1 5m depth for 24 hours there should be no breakdown or arc over between the metallic components of the FOSC between metallic components...