7.3.
SEAL REPLACEMENT: VERTICAL SEAL
Remove all logs from the frame.
Remove the “Seal and guide Locking System”.
Remove the vertical seals and replace by the new ones. For stainless steel frames, the seals are secured with
stainless steel retainers.
Secure the Locking System in position, making sure the seal is in compression against the bottom part of the
frame.