Sensitive measuring devices must be checked from time to time for accuracy and leakage. We recommend
that the performance should be checked every 2 years.
GUIDANCE AND MANUFACTURE’S DECLARATION
ELECTROMAGNETIC EMISSION
The Digital Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The
customer of the user of the Digital Blood Pressure Monitor should assure that it is used in such an environment.
Emission test
Compliance
Electromagnetic environment – guidance
Radio frequency (RF) emissions
CISPR 11
Group 1
The Digital Blood Pressure Monitor use RF energy only for
its internal function. Therefore, its RF emissions are very
low and are not likely to cause any interference in nearby
electronic equipment.
RF emissions
CISPR 11
Class B
The Digital Blood Pressure Monitor is suitable for use in all
establishments other than domestic and those directly
connected to the public low-voltage power supply network
that supplies buildings used for domestic purposes.
Harmonic emissions
IEC 61000-3-2
Not applicable
Voltage fluctuations/flicker
emissions
IEC 61000-3-3
Not applicable
ELECTROMAGNETIC IMMUNITY
The Digital Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The
customer or the user of Digital Blood Pressure Monitor should assure that it is used in such an environment.
Immunity test
IEC 60601
Test level
Compliance
level
Electromagnetic environment - guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
± 6 kV
contact
± 8 kV air
± 6 kV
contact
± 8 kV aie
Floors should be wood, concrete or ceramic tile. If floor are covered
with synthetic material, the relative humidity should be at least 30%.
Power frequency
(50Hz/60Hz)
magnetic field IEC
61000-4-8
3 A/m
3 A/m
Power frequency magnetic fields should be at levels characteristic of
a typical location in a typical commercial or hospital environment.
Radiated RF
IEC 61000-4-3
3 A/m
80 MHz a
2.5 GHz
3 A/m
Portable and mobile RF communications equipment should be used
no closer to any part of the Digital Blood Pressure Monitor, including
cables, than the recommended separation distance calculated from
the equation applicable to the frequency of the transmitter.
Recommended separation distance
d=1.167
√
P
80 MHz to 800 MHz
d=2.333
√
P 800 MHz to 2.5 GHz
Where
P
is the maximum output power rating of the transmitter in
watts (W) according to the transmitter manufacturer and
d
is the
recommended separation distance in metres (m).
Field strengths from fixed RF transmitters, as determined by an
electromagnetic site survey
A
, should be less than the compliance
level in each frequency range
B
Interference may occur in the vicinity of
equipment marked with the following symbol: