Hard Disk Drive Events
Monitoring Components and Identifying SNMP Messages
265
Messages and Descriptions
Component Name
Oracle ILOM Event Message:
Upper critical threshold no longer exceeded
Severity and Description:
Informational; A temperature sensor has reported that its value has
gone below an upper critical threshold setting or above a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS
Related Information
■
“System Chassis Components” on page 253
■
“Cooling Unit Components” on page 255
■
“Disk Backplane Components” on page 255
■
“Memory Device Components” on page 256
■
“Power Unit Components” on page 257
■
“Processor Components” on page 258
■
“System Board Components” on page 259
■
“Hard Disk Drive Components” on page 262
Hard Disk Drive Events
The following table lists hard disk drive events.
Messages and Descriptions
Description
SNMP Trap Message:
sunHwTrapSlotOrConnectorError
Oracle ILOM Event Message:
Assert
Severity and Description:
Major: A sensor associated with a slot or connector has detected an error.
/SYS/DBP/HDD[0-x]/STATE
SNMP Trap Message:
sunHwTrapSlotOrConnectorOk
Oracle ILOM Event Message:
Deassert
Severity and Description:
Informational; A sensor associated with a slot or connector has returned
to its normal state.
/SYS/DBP/HDD[0-x]/STATE
Related Information
■
“System Chassis Components” on page 253
■
“Cooling Unit Components” on page 255
■
“Disk Backplane Components” on page 255
■
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...