Mark the Rackmount Location
Callout
Description
1
Chassis front
2
Slide-rail lock
3
Mounting bracket
4
Mounting bracket clip
2.
With the heads of the five chassis locating pins protruding through the five
keyhole openings in the mounting bracket, pull the mounting bracket toward
the front of the chassis until the mounting bracket clip locks into place with an
audible click.
3.
Verify that the rear locating pin has engaged the mounting bracket clip.
4.
to install the remaining mounting bracket on the
other side of the storage server.
Related Information
■
“Mark the Rackmount Location” on page 31
■
“Attach Tool-less Slide-Rail Assemblies” on page 35
Mark the Rackmount Location
Use the rackmount installation card to identify the correct mounting holes for the slide-rails.
Note -
Load the rack from bottom to top.
1.
Ensure that there is enough vertical space in the cabinet to install the storage
server.
“Rack Requirements” on page 20
2.
Place the rackmount installation card against the front rails.
Installing the Storage Server Into a Rack
31