5
INSTALLATION
Install the stove in accordance with the requirements given below. If a concealed gas connection is
to be made prepare the pipe work prior to installing the stove.
Positioning the Stove
Clearances from non-combustible material must be at least 120mm on both sides and 75mm at the
back. Clearances for combustible material must be at least 200mm on both sides and 100mm at the
back.
Hearth
A hearth is not required for this stove. The stove must stand on a solid floor, either combustible or
non combustible. Care should be taken to ensure that nothing combustible, such as carpets, soft
furnishings, curtains, shelves, etc., are positioned within the minimum distances to combustibles as
stated in the paragraph above.
Log Arrangement
The logs should only be arranged as shown in the layout given in the Installation Instructions by a
qualified person. The stove must only be fitted with the ceramics supplied. DO NOT use any extra
logs or coals.
Flue Connection
The flue should be a minimum of 3metres high and at least 125mm diameter or equivalent area.
Horizontal or negative gradients in the flue pipe should be avoided.
It is recommended that a minimum height of 600mm from the stove should be established before
any significant change in the direction of the flue.
The flue must be lined.